SPECIFICATIONS
Model No.
HC25
INSTALLATION
OPERATION
B
C
Capacity
Effective
2
Tons
Area in
2
(cm
)
1.00
1.00
(6,45)
3
Attach hose to
/
" NPT port. Connect mating coupler halves together hand tight only.
8
Using tools will damage the coupler.
CAUTION
Position hoses to avoid sharp bends, kinks, and sharp impacts from
objects because they may cause wear or damage to the hose, leading
to premature failure.
Refer to the instruction sheet supplied with your pump for information on installing and
operating your pump.
Check the oil level in the pump.
1.
Make sure all connections are tight and leak free.
2.
Remove air from the system by placing the cylinder at a lower level than the pump
3.
and cycling the cylinder several times until the motion is smooth.
Operate the pump to spread the cylinder jaws. The jaws will close automatically
4.
when the pressure is released. The speed of retraction is dependent on the length of
the hose and other restrictions in the line.
CAUTION
Keep hands away from the pivot point (A) of
spreader jaws.
WARNING
DO NOT handle pressurized hoses. Escaping oil
under pressure can penetrate the skin, causing
serious injury. If oil is injected under the skin, see a
doctor immediately.
A
HC25
Stroke
A
in. (cm)
in (cm)
in (cm)
3.50 (8,89) 8.78 (22,3)
3
B
C
Oil Capacity
3
3
in (cm)
in
(cm
3.70
0.38
0.61
(9,40)
(0,97)
(10,0)
Weight
)
lbs (kg)
5.00
(2,27)
A