DIGITAL RADIO CONTROL WITH PROGRAMMABLE CODE S476
Description
The S476 Radio control system consists of one or more transmitters and
one or more receivers which can be combined to meet the specific needs
of the client.
The various receiver models offer the following possibilities: up to 4 channels
and a number of possible combinations equal to 19683, (these are program-
mable through the use of a block of 9 three-way dip-switches).
Use
The S476 radio control allows the remote activation of electrical and elec-
tronic appliances with its best use in the following areas: automatic opening
systems and in all systems which require remote control activation (without
wires) using secret codes.
Transmitter versions
TRS476200
Pocket size transmitters
TRS476400
Pocket size transmitters
Receiver versions
RCS476100
Outdoor receivers
RSS476200
Slot-in receiver cards
RMS476200
Mini receiver + container
Receiver antenna installation
Minimum and maximum range of the radio controls.
'Range' is intended to mean the working distance, measured in free space,
between the receiver and the transmitter with the antenna installed.
The range is therefore closely linked to the technical characteristics of the
system (power and sensibility) and varies according to the characteristics
of the site in which the system is located.
It therefore follows that to obtain the best results from the radio control
the installation sites for the receiver and the antenna should be carefully
chosen.
It is not possible to install 2 receivers at a distance of less than 1,5m from
each other. It is good practise to position the receiver away from computer
systems, alarm systems and other possible sources of disturbance.
(A bad choice of positioning could compromise the performance of the
receiver).
Antenna
The installation of the antenna is fundamental, connected to the receiver it
represents the reception point for the radio control.
When installing the antenna the following points should be observed:
- only use a tuned antenna ANS400 connected to the receiver using a coaxial
cable RG58 (impedance 50Ω) with a maximum length of 15m;
- the antenna should be positioned out of doors in the highest possible point,
visible and away from metal structures.
Note: If for some particular reason it is not possible to fit an antenna, a
reasonable performance can be obtained by connecting a 170mm piece of
single pole conductor wire (Ø1mm) to the receiver.
RECEIVERS
Warning! The receivers must only be powered by a safety power pack. The
use of non safety power packs could provoke damage to the system.
Outdoor receivers IP55 (fig. 1)
The receiver is fitted with a 12-way terminal board (printed circuit CS1291A/B
- fig.1) with the following electrical connections:
12V ac/dc between binding posts 11-12
24V ac/dc between binding posts 10-12
PW
The Led
will light up when the electronic card is receiving power.
The case type receiver is fitted using "fast-fitting" brackets. The bracket
should be fixed to the wall using two raw plugs (check that it is in square).
After connecting the wiring the case should be slid onto the bracket therefore
fixing it to the wall.
If any repair work is necessary the case can be easily extracted by pushing
upwards the action of which will separate it from the bracket.
Interchangeable channel modules
In the receivers the channel functions are printed on the circuit board. The
interchangeable channel modules can only have the following configurations
and must not be mixed:
- from 1 to 4 impulsive relay strips MCC4491R0 1 channel
- one ON-OFF relay strip MCC0381M0
- one timer relay strip MCC0381T0
+39/0438.404011-401818
+39/0438.401831
Sales.office.it@cardin.it
Sales.office@cardin.it
www.cardin.it
2 channels
4 channels
4 channels
2 channels
2 channels
1 channel ON-OFF
1 channel 0,5 to 120 seconds
SERIAL NUMBER
ZVL214.06
The S476 series conforms to the essential requirements of the directive 99/05/CE
and the technical reference standards have been applied.
Frequency validity: 433.92 MHz for all
Slot-in receiver cards (fig. 2)
Warning! The receiver cards must be sufficiently insulated from the parts of
the host device which are powered by the mains.
- The receiver card (CS1310A/B) is inserted directly into an appliance which
is designed to receive and has the following electrical connections:
12V ac/dc with jumper "J1" in position "B"
24V ac/dc with jumper "J1" in position "A"
The receiver cards are fitted with two relays, the outputs of which are marked
CH1 (normally open contact) and CH2 (normally open/normally closed
contact)
The relays CH1 and CH2 can be activated by selecting the functions A-B-C-D
and made to correspond with the transmitter channels CHA-CHB-CHC-CHD
by setting the jumpers situated on the circuit board (see fig. 5, 6).
Mini receivers IP20 (fig. 3)
- The mini receiver (CS1309A/B) is housed in an indoor container, it is fitted
with an 10-way terminal board and has the following electrical connec-
tions:
12V ac/dc between binding posts 7-8
24V ac/dc between binding posts 6-8.
The mini receivers are fitted with two relays, the outputs of which are marked
CH1 (N.O. contacts) and CH2 (N.O.-N.C. contacts).
The relays CH1 and CH2 can be activated by selecting the functions A-B-C-D
and made to correspond with the transmitter channels CHA-CHB-CHC-CHD
by setting the jumpers situated on the circuit board (see fig.3).
PROGRAMMING THE TRANSMITTER USER CODE
The transmitters and receivers are supplied with a block of 3-way dip-switches
with which to program the digital codes for each system. Programming can
be carried out more than once, even after the installation, thus ensuring the
total secrecy of the user code. To ensure an exact match between the trans-
mitter and receiver codes when programming the 2 and 4 key transmitters
coupled with receivers with up to 4 channels remember to set the same code
in both the receiver and the transmitter using all the 9 available DIPS (19683
possible combinations). It is important to remember that the receivers can
only respond to one signal at a time.
IT FOLLOWS THEREFORE THAT MULTIPLE FUNCTIONS CANNOT BE USED
CONTEMPORANEOUSLY.
TRANSMITTERS (fig. 5, 6)
In the transmitters each key corresponds to a different channel, with the
sole exception of the two key transmitters where it is possible to have the
same channel for both keys. (single-channel operation). For double-channel
operation which can be obtained using the second key, set the two-way DIP
switch, located separately from the nine-way user code DIP switch on the
printed circuit board. Once the transmitter's functions have been programmed
or recognized, make sure that every STRIP in the outdoor receiver (which
carries the relay) corresponds to the desired function.

TECHNICAL SPECIFICATIONS

RECEIVER
- reception frequency ................................................................. 433.92MHz
- local oscillation frequency ..................................................... 433.42MHz
- local oscillation emission ................................................ <-57dBm (<2nW)
- intermediate frequency IF .............................................................. 500kHz
- antenna impedance in input ................................................................50Ω
- sensitivity (finely tuned signal) ............................................................. 1µV
- power supply .......................................................................12-24V ac/dc
- power consumption at rest ............................................................... 20mA
- power consumption with active relay ............................................... 50mA
- maximum commutable power at the relay with resistive load:
load ac/dc .................................................................................60VA/24W
maximum voltage ..................................................................... 30V ac/dc
- excitation delay ................................................................................150ms
- dropout delay ...................................................................................150ms
- operating temperature range ................................................. -20°...+60°C
TRANSMITTERS
- carrier frequency ...................................................................... 433.92MHz
- carrier frequency tolerance ............................................................ ±75kHz
- band width ..................................................................................... >25kHz
- apparent radiated power .................................. -10...-7dBm (100-200µW)
- apparent power harmonic products ............................... <-54dBm (<4nW)
- modulation ....................................................................................AM/ASK
- signal modulation .............................................................. PCM, 1.3ms/bit
- power supply (Alkaline battery GP23A) ....................................12V ± 10%
- maximum power consumption ......................................................... 25mA
- operating temperature range ................................................. - 10...+55°C
- relative humidity ................................................................................<95%
SERIES
MODEL
S476
AM
29-03-2004
countries
DATE

Publicidad

loading