sauermann CP 110 Guia De Inicio Rapido página 4

Ocultar thumbs Ver también para CP 110:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CP 114, CP 115
1
1
2
2
3
3
4
4
Combination 1
Combination 2
Type of transmitter
CP114
CP115
CP114
CP115
mbar
100
500
200
750
inWG
40.0
200.0
80.0
300.0
kPa
10.0
50.0
20.0
75.0
PSI
2.0
10.0
4.0
15.0
mmHg
80
400
160
600
mmH
O
1 000
5 000
2 000
7 500
2
daPa
1.0
5.0
2.0
7.5
hPa
100
500
200
750
 
• Measuring ranges of the CP
114 transmitter on the ±500 mbar range according to the measurement unit.
 
• Measuring ranges of the CP
115 transmitter on the ±2000 mbar range according to the measurement unit.
Example:
• From 0 to 750 mmH
O, measuring range is 750 mmH
O.
2
2
• From -500 mbar to +500 mbar, measuring range is 1000 mbar.
Standard range / central zero setting – left DIP switch
Please follow carefully the combinations beside
with the DIP switch. If the combination is wrongly
done, the following message will appear on the display
of the transmitter "CONF ERROR". In that case, you will
have to unplug the transmitter, place the DIP switches
correctly, and then power the transmitter up.
Output setting – right DIP switch
(CP 111/112/113/114/115 – AO and CP 111/112/113 – AN models)
To set the type of analogue output, please put the on-off
switch of the output as shown beside.
Units setting – right DIP switch
To set a measurement unit, put the on-off switches 2, 3 and 4 of the units as shown in the table below.
CP 111, CP 112, CP 113
Configurations
Pa
mmH
O
mbar
2
1
1
1
1
Combinations
2
2
2
2
3
3
3
3
4
4
4
4
CP 114, CP 115
Configurations
mbar
inWG
kPa
1
1
1
1
Combinations
2
2
2
2
3
3
3
3
4
4
4
4
1
1
1
2
2
2
3
3
3
4
4
4
Combination 3
Combination 4
Combination 5
CP114
CP115
CP114
CP115
CP114
CP115
300
1 000
400
1 500
500
2 000
120.0
400.0
160.0
600.0
200.0
800.0
30.0
100.0
40.0
150.0
50.0
200.0
6.0
20.0
8.0
30.0
10.0
40.0
240
800
320
1 200
400
1 600
3 000
10 000
4 000
15 000
5 000
20 000
3.0
10.0
4.0
15.0
5.0
20.0
300
1 000
400
1 500
500
2 000
Configurations
Full scale
Central zero
Combinaisons
Example:
• 0 - 100 Pa:
Full scale / 0
(0 / 100 Pa)
Central zero
(-50 Pa / 0 / +50 Pa)
Configurations
4-20 mA
0-10 V
1
1
2
2
Combinations
3
3
4
4
InWG
mmHG
daPa
kPa
hPa
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
PSI
mmHG
mmH
O
daPa
hPa
2
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
Configuration via LCC-S software (option)
An easy and friendly configuration with the software!
You can configure your own intermediary ranges.
The minimum difference between the high range and the
low range is 20.
For example, it is possible to set the instrument from -20 to 0 Pa, from
0 to +20 Pa, or from -10 to +10 Pa...
To access the configuration via software: set the DIP switches as
shown beside.
Note: the on-off switch 1 of the right DIP switch can be in any position
(selection of the analogue output 0-10 V or 4-20 mA).
Connect the cable of the LCC-S to the connection of the transmitter.
The configuration of the parameters can be done either
with the DIP switch or via software (you cannot combine both
solutions).
Mounting
To mount the transmitter, mount the ABS plate on the wall (drilling:
Ø 6 mm, screws and pins are supplied).
Insert the transmitter on the fixing plate (see A on the drawing
beside). Rotate the housing in clockwise direction until you hear a
"click" which confirms that the transmitter is correctly installed.
Once the transmitter is installed and powered up, please
make an autozero to guarantee the correct working of the
transmitter in any position.
Accessories
Please refer to the data sheet to get more information about available accessories.
Maintenance: please avoid any aggressive
Precautions for use: please always use the device
solvent. Please protect the transmitter
in accordance with its intended use and within
and its probes from any cleaning product
parameters described in the technical features in order
containing formalin, that may be used for
not to compromise the protection ensured by the
cleaning rooms or ducts.
device.
Configuration via PC
1
1
2
2
3
3
4
4
Left DIP switch
Right DIP switch
Refer to the user manual of the
LCC-S to make the configuration.
75 mm
37.5 mm
40 mm
8 mm
A
4.5 mm
14 mm
A
7.5 mm