Balluff BSP B S1B Serie Manual Del Usuario página 27

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Pressure Sensors with IO-Link
BSP-B... /-V...
IO-Link interface
Parameterization data
Index
ubindex
S
hex
hex
0x3C
0x01
Setpoint 1 = SP1
0x3C
0x02
Setpoint 2 = rP1
0x3E
0x01
Setpoint 1 = SP2
0x3E
0x02
Setpoint 2 = rP2
0x60
0x00
Password
0xD0
0x00
Delay switching time 1
0xD1
0x00
Delay back switching time 1
0xD2
0x00
Delay switching time 2
0xD3
0x00
Delay back switching time 2
0xD5
0x00
Min pressure value
0xD6
0x00
Max pressure value
0xD7
0x00
Measure damping
www.balluff.com
Object name
Access
R/W
R/W
R/W
R/W
W
R/W
R/W
R/W
R/W
R
R
R/W
Length
Value range
2 bytes
Process data
2 bytes
Process data
2 bytes
Process data
2 bytes
Process data
4 bytes
0000...9999
2 bytes
0...500
2 bytes
0...500
2 bytes
0...500
2 bytes
0...500
2 bytes
Process data
2 bytes
Process data
2 bytes
0...1000
in 10 ms
increments
Gradi-
Unit
Default
ent
100%
0%
100%
0%
0
0.1
sec
0
0.1
sec
0
0.1
sec
0
0.1
sec
0
1
MS
0
English
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bsp v s1b serie

Tabla de contenido