Install two new 5/16" diameter T-bolts into the closet
flange.
TO INSTALL THE SUPPLY SHUT-OFF
VALVE
Install the supply shut-off valve so it is 8" (20.3cm) above
the finished floor for all models other than the K-3427.
Install the supply shut-off valve 10" (25.4) above the
finished floor for the K-3427. The supply shut-off valve
must be 5-1/8" (13cm) to the left of the closet flange
centerline.
The centerline of the supply shut-off valve outlet should
extend 3-1/4" (8.3cm) from the finished wall. Install the
supply shut-off valve with the outlet vertical.
TO INSTALL THE TOILET
Set the toilet upside down on some padding. Firmly press
the toilet gasket around the toilet outlet.
NOTE: If you are using a toilet gasket with an integral
plastic sleeve, make sure the gasket is positioned with the
sleeve facing away from the toilet.
If you temporarily plugged the closet flange with a rag,
remove the rag now.
Carefully align and lower the toilet over the closet flange
and T-bolts. Apply full body weight to the toilet rim to set
the seal.
NOTE: To achieve optimum performance, be sure the
toilet is level.
CAUTION: Risk of external leakage. Do not lift
or rock the toilet after the seal is set - a new toilet
gasket must be installed if you break the watertight
seal.
A
1007285-2-
T-Bolts
3-1/4" (8.3cm)
8" (20.3cm)
(10" (25.4cm)
for K-3427)
12" (30.5cm)
(10" (25.4cm) for K-3432)
Toilet Outlet
Toilet Gasket
Closet Flange
3
Closet Flange
Fig. #3
Supply Shut-Off
Valve
5-1/8" (13cm)
Closet Flange
Centerline
Fig. #4
T-Bolt
Fig. #5