AIRLOCK
This pump (A) is a centrifugal utility pump, designed to efficiently remove water.
However, it cannot move air. If air is trapped inside the pump (a condition called
"airlock"), the pump cannot pump water out even though the pump is completely
submerged. This adapter (included) has an anti-airlock hole. Air flows out through the
anti-airlock hole, eliminating the airlock so that the pump can operate properly. If debris
blocks the anti-airlock hole, unplug the pump, clean out the anti-airlock hole, and restart
the pump. Alternately, drain the water out of the garden hose, keep the end of the hose
out of the water, and plug in the power cord, restarting the pump.
CAUTION: This hole is for anti-airlock purposes only. Leakage of air or water is normal and
necessary.
DO NOT REMOVE OR PLUG THIS HOLE!

CARE AND CLEANING

CAUTION: Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, unplug the pump
and allow time for it to cool after periods of extended use.
Do
When the power is disconnected, inspect the pump
suction screen and remove all debris, then plug the
pump back into the grounded (GFCI) outlet.
To clean a pump clogged with debris:
Unplug the pump from electrical power.
Remove the screws (6) and take out the bottom plate (5) from the pump
Remove debris from the screen.
Remove the screws (4) and take out the volute (3) from the pump and clean
the debris on the impeller (1).
Reassemble the volute (3).
6
Do Not
Do not disassemble the motor housing. This motor
has NO repairable internal parts, and disassembly
may cause leakage or dangerous electrical wiring
issues.
Do not lift up the pump by the power cord.