Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

MODEL VDVE1200
EXTERIOR MOUNTED BLOWER
FOR USE WITH MODELS VDD5300, CVDD5300, VDD5360, CVDD5360, VDD5450,
CVDD5450, VDD5480, CVDD5480 DOWNDRAFT VENTILATORS.
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manu-
facturer. If you have questions, contact the manufacturer
or your distributor.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be
locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
a qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National
Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
PLAN THE
INSTALLATION
ALL INSTALLATIONS
1. Locate the blower so the
length of the duct run and
number of elbows needed
are kept to a minimum.
2. Where possible, blower
should be centered be-
tween wall studs or roof
rafters.
3. Avoid pipes, wires, or other
ductwork that may be run-
ning through the wall.
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
MODEL VDVE1200
MODEL VEDV1200
EXTERIOR BLOWER
EXTERIOR BLOWER
10" ROUND
DUCT
TO
DOWNDRAFT
TYPICAL ROOF MOUNTED INSTALLATION
WARNING
5. When cutting or drilling into wall, or ceiling, do not dam-
age electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
CAUTION
1.
For general ventilating use only. Do not use to exhaust haz-
ardous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further informa-
tion and requirements.
4. Electrical circuit, including speed control, (if used), must be
rated 6 AMPS minimum.
Blower Dimensions
22 x 30.828 x 12.724
SPECIFICATIONS
MODEL
VOLTS
VDVE1200
120
TO
DOWNDRAFT
TYPICAL WALL MOUNTED INSTALLATION
AMPS
CFM
DUCT SIZE
3.0
1200
10" DIA.
10" ROUND DUCT
MODEL
MODEL
VEDV1200
VDVE1200
EXTERIOR
EXTERIOR
BLOWER
BLOWER

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Viking Range VDVE1200

  • Página 1 MODEL VDVE1200 EXTERIOR MOUNTED BLOWER FOR USE WITH MODELS VDD5300, CVDD5300, VDD5360, CVDD5360, VDD5450, CVDD5450, VDD5480, CVDD5480 DOWNDRAFT VENTILATORS. READ AND SAVE THESE INSTRUCTIONS WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, 5. When cutting or drilling into wall, or ceiling, do not dam- OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: age electrical wiring or other hidden utilities.
  • Página 2 PREPARE THE INSTALLATION PREPARE THE INSTALLATION LOCATION LOCATION ROOF INSTALLATIONS WALL INSTALLATIONS 1. Choose a position on the outside wall. Make sure that 1. Locate the blower on the rear slope of the roof. Place it no wall studs, pipes or wires run through the opening in a location to minimize duct run.
  • Página 3 INSTALL THE BLOWER INSTALL THE BLOWER ROOF INSTALLATIONS WALL INSTALLATIONS 1. Remove the cover and screws. 1. Place a large bead of caulk on the back side of the housing all along the outer edges. 2. Attach an appropriate U.L. approved cable connector in the hole at the rear of the wiring box.
  • Página 4 Be careful not to bend or otherwise damage downdraft. blower wheel. NOTE: Use duct tape to make ductwork connections secure and air tight. MOTOR LUBRICATION The motor is permanently lubricated. Do not oil or disas- semble motor. VIKING RANGE CORPORATION GREENWOOD, MISSISSIPPI 38930 USA 99045285A...
  • Página 5 MODÈLE VDVE1200 VENTILATEUR MONTÉ À L’EXTÉRIEUR POUR UTILISATION AVEC LES MODÈLES VDD5300, CVDD5300, VDD5360, CVDD5360, VDD5450, CVDD5450, VDD5480, CVDD5480 VENTILATEURS À TIRAGE VERS LE BAS SEULEMENT VEUILLEZ LIRE LES DIRECTIVES ET LES CONSERVER AVERTISSEMENT AVERTISSEMENT 7. Pour réduire les risques d’incendie, utilisez seulement des OBSERVEZ LES DIRECTIVES CI-DESSOUS DE MANIÈRE...
  • Página 6 PRÉPARATION DE L’EMPLACEMENT PRÉPARATION DE L’EMPLACEMENT DE POSE DE POSE POSES SUR LES TOITS POSES SUR LES TOITS 1. Choisissez un emplacement de pose pour le ventilateur sur la pente Choisissez un emplacement sur le mur extérieur. Assurez-vous arrière du toit. Placez-le dans un emplacement réduisant au maximum qu’aucun poteau mural, tuyau ou câble ne passe au niveau l’utilisation de conduits.
  • Página 7 POSE DU VENTILATEUR POSE DU VENTILATEUR ROOF INSTALLATIONS WALL INSTALLATIONS 1. Mettez une large bande de produit à calfeutrer à l’arrière 1. Retirez le couvercle et les vis. du boîtier le long des rebords extérieurs. 2. Fixez un connecteur de câble homologué U.L.dans 2.
  • Página 8: Utilisation Et Entretien

    Le moteur est lubrifié en permanence. Il ne doit pas être REMARQUE : Utilisez du ruban pour canalisations pour fixer huilé ni démonté. solidement tous les raccords des conduits et les étancher. VIKING RANGE CORPORATION GREENWOOD, MISSISSIPPI 38930 USA 99045285A...
  • Página 9: Ventilador De Montaje Exterior Modelo Vdve1200

    VENTILADOR DE MONTAJE EXTERIOR MODELO VDVE1200 PARA USARSE ÚNICAMENTE CON EL VENTILADORS DE TIRO DESCENDENTE MODELOS VDD5300, CVDD5300, VDD5360, CVDD5360, VDD5450, CVDD5450, VDD5480, CVDD5480. LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS 5. Al cortar o perforar a través de la pared o del cielo raso, no dañe ELÉCTRICAS O LESIONES PERSONALES, OBSERVE LAS...
  • Página 10: Prepare El Lugar De La Instalación

    PREPARE EL LUGAR DE PREPARE EL LUGAR DE LA LA INSTALACIÓN INSTALACIÓN INSTALACIONES EN EL TECHO INSTALACIONES EN LA PARED Ubique el ventilador en la pendiente posterior del techo. Colóquelo Seleccione un lugar en la pared exterior. Asegúrese de que no en un área en la cual minimice la longitud del tramo de conducto.
  • Página 11: Instale El Ventilador

    INSTALE EL VENTILADOR INSTALE EL VENTILADOR INSTALACIONES EN EL TECHO INSTALACIONES EN LA PARED 1. Quite la cubierta y los tornillos. 1. Coloque un reborde grande de material de calafateo en el lado posterior de la cubierta, a lo largo de todos los bordes externos. 2.
  • Página 12: Uso Y Cuidado

    NOTA: Coloque cinta en todas las conexiones de los conductos para LUBRICACIÓN DEL MOTOR asegurarlas y hacerlas herméticas. El motor está permanentemente lubricado. No lubrique ni desarme el motor. VIKING RANGE CORPORATION GREENWOOD MISSISSIPPI 38930 USA 99045285A...

Tabla de contenido