Descargar Imprimir esta página

Interface Description - ABB W2256 BL Manual Del Usuario

Ocultar thumbs Ver también para W2256 BL:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
M A N U A L

Interface description

7
6
5
4
3
2
1
13
12
1
2
2
7
3 4
8
9
5
No.
Description
1
Connector for device software update
2
Rotary switch to set the address of outdoor station (1-9)
3
Set feedback tone of pushbutton ON/OFF
4
Set general call to all indoor stations in one family: ON/OFF
11
If GC=ON, press button 1/button 2, all IS ring
10
5
Configurate round pushbutton
9
3 -> OFF; 4 -> OFF = Call IS 001
8
Set the video mode PAL/NTSC
6
OFF = PAL video mode
ON = NTSC video mode
7
Set default lock
OFF = set (Lock-GND) as default lock
ON = set (COM-NC-NO) as default lock
*Default lock is controlled by "unlock" button on IS
8
Plug-in clamps (a, b) for bus connection
9
Plug-in clamps (Exit-GND) for exit button
10
Plug-in clamps (Lock-GND) for door opener
11
Plug-in clamps (COM-NC-NO) for floating output, door opener
12
Rotary switch to adjust default door lock release time, 1-10s
13
Rotary switch to adjust loudspeaker volume
No.
Description
Outdoor station selector switch
1
Set the address of the default outdoor station.
2
2
Indoor station selector switch (1...250)
2
Selector switch X10 sets tens digits, selector switch X1 sets units
digits, Dip switches X100 and X200 set hundreds digits.
Master/slave function switch
3
Only one indoor station in each apartment can be set as "Master"
(ON position).
Terminal resistor switch
4
In video installations or mixed audio and video installations, the
switch must be set as 'RC on' on the last device of the line (ON
position).
6
5
a, b = bus connector
6
A potential free contact, such as a doorbell pushbutton
7
Setting button
Press to enter setting mode.
8
Microphone
9
Speaker
5

Publicidad

loading