ART 7W/G2+ MONITOR
SAFETY PRECAUTIONS
Always disconnect the power supply
-
before installing or making modifications to the device.
.
- The fitting and handling of these devices must be carried out by
.
- The wiring must run at least 40 cm. away from any other wiring.
- Do not overtighten the screws on the connector.
- Install the monitor in a dry protected location free from the risk of dripping or splashing water.
- Do not place in humid, dusty or smoky locations, or near sources of heat.
- Before connecting the device to the mains, check the connections between the door panel, power
supply, distributors and monitors.
-
Always follow the instructions contained in this manual.
CHARACTERISTICS
( )
*
-
Hands-free monitor.
-
7" TFT c
olo r
u screen
.
- Touch screen for access and selection of menu function.
-
Wifi transmission monitor to call transfer to mobile
- Monitor
with simple installation (non-polarised 2 wires bus)
-
User menu
.
-
Installer menu
.
-
Image and communication settings menu
.
-
Output auxiliary call repeater (max.
50mA/12V ).
-
Input for calls from apartment front door
.
- Door release 1 and 2 activation icons screen.
-
Notification l
eds.
-
Configuration switches to assign the address and to define whether the monitor is master or slave
SYSTEM OPERATION
( )
*
-
To make a call, the visitor must press the button of the apartment; an audible sound indicates that the
call is being made and LED
will turn on. If vocal synthesis is enabled, a 'Call is in progress' message
appears indicating that a call is being made. At this moment, the apartment's monitors receive the call.
If another apartment is called by mistake, press the button for the correct apartment and the first call
will be cancelled.
- Upon receiving the call, the image will appear on the screen of the master monitor (and slave 1, if it
exists) without the visitor knowing and icon
image from slave monitors 2 or 3, press the screen for the image to appear. If the call is not answered
within 45 seconds, LED
will turn off and the system will become free.
- To establish communication, press off-the-hook icon
and the led
will
turn on
.
- Connection will last for 90 seconds or until on-the-hook icon
communication ends, LED
will turn off and the system will become free. If vocal synthesis is enabled,
a 'Communication is finished' message will indicate that the call is over.
-
To open door
ó
of the door panel
,
press the corresponding icon
1
2
communication processes: one press will activate the lock release for seconds and LED
turn on for seconds. If vocal synthesis is enabled, a 'Door
3
door panel.
-
Detailed operation
and configuration
of the monitor
INSTALA
TION OF THE
MONITOR
( )
*
( ) For more information, see
"TART 7W/G2+
*
https://doc.golmar.es/search/manual/50122463
authorised personnel
.
smartphone.
.
dc
displayed on the screen will blink green. To view the
on the screen. Door panel LED
will turn off
is pressed
on the screen
on the screen
during the call or
3
is
open' message will be indicated on the
, see "TART TW/G2+" user manual
.
user manual
(cód. 50122463)".
2
ART 7W/G2+ MONITOR
DESCRIP
TION
( )
*
A
B
C
D
I
J
K
I
( )
Monitor address (code) setup:
*
.
Dip1 Dip5:
-
Sets the monitor address (addresses to 3 ).
The switches set to OFF have a zero value. The values of the switches set to ON are shown in the table below. The
monitor code is the sum of the values of the switches set to ON.
Important: Apartment 1 (Dip1 to ON & Dip2-Dip5 to OFF)
ART 7W/G2+ monitor
Important: Apartment 32 (Dip1 - Dip5 to OFF).
Dip6-Dip7: These define whether the monitor is master or slave. Each apartment must have one master monitor, and only
one. In the case of apartments with more than one monitor, the monitor with Wi-Fi transmitter should always be the master.
Master
ON
1
2
3
4
5
6
7
Dip8: This activates the end-of-line resistance in the ON position. Activate it in monitors where the bus cable
ends. Deactivate it only in intermediate monitors.
Dip1 to Dip5: These assign the address of the corresponding monitor to its call button on the door
panel. Switches 4-5 must remain in the OFF position.
. When
Apartment 1
1 ( )
ON
1
2
3
4
5
6
7
1 ( )
Apartment 1 (Dip1 to ON) ART 7W G2+ monitor with V.04 and later.
will also
Dip6-Dip7: These define whether the monitor is master or slave. Each apartment must have one master monitor, and only
one. In the case of apartments with more than one monitor, the monitor with Wi-Fi transmitter should always be the master.
Master
ON
1
2
3
4
5
6
7
Dip8: This activates the end-of-line resistance in the ON position. Activate it in monitors where the bus cable ends.
Deactivate it only in intermediate monitors.
( ) For more information, see
*
https://doc.golmar.es/search/manual/50122463
EN
MONITOR
A.
Speaker.
B.
Notification icons:
Power on indicator.
Do not disturb.
Auxiliary relay activated.
Door opening.
E
New image/video.
Wi-Fi transfer activated.
C.
F
Hidden start/stop communication button:
Note:
ART 7W/G2+ monitor 'V.01 + No. 6539 and
V.02' or later:
G
deactivated (see "TART 7W G2+" manual, code
H
50122463).
D.
Raised dots for the visually impaired.
E.
Touch screen.
F.
Hidden door opening button.
Note:
ART 7W/G2+ monitor 'V.01 + No. 6539 and
12210710
V0
5
Product Version:
V.02' or later:
MONITOR 7" WIFI ART 7W/G2+
I
GOLMAR S.A.
CAUTION
C/ Silici, 13
deactivated (see "TART 7W G2+" manual, code
TO PREVENT ELECTRIC SHOCK,
WARNING
08940 - SPAIN
DO NOT REMOVE COVER. NO
TO PREVENT FIRE OR ELECTRIC
USER SERVICEABLE PARTS
SHOCK, DO NOT EXPOSE THIS
INSIDE. REFER SERVICING TO
DEVICE TO RAIN OR MOISTURE
QUALIFIED SERVICE PERSONNEL.
50122463).
ON
UID: mnvx8d8uskpv
G.
1
2
3
4
5
6
7
8
MicroSD card slot
L
SA
BUS
GND
BUS
Type: MicroSD Class 10 from 4Gb to 128 Gb.
HZ
24V
K
HZ
GND
H.
Microphone.
DIP 8
I.
I
Wall mounting connector fixing (x4).
J.
Configuration switches.
K.
Installation terminals
L.
UID code label of the monitor
Building / Villa (Nexa Door Panel)
1
2
Table of values
with V.04 and later
.
Switch number:
1
2
Value when ON
:1
2
Slave 1
Slave 2
ON
ON
8
1
2
3
4
5
6
7
8
1
2
3
4
5
Villa (Soul Door Panel)
*
Apartment 2
Apartment 3
ON
ON
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Slave 1
Slave 2
ON
ON
8
1
2
3
4
5
6
7
8
1
2
3
4
5
"TART 7W/G2+
user manual
(cód. 50122463)".
3
For the visually impaired, by default
For the visually impaired, by default
(not included).
.
.
ON
3
4
5
1
2
3
4
5
6
7
8
4
8 16
Example: 0+ 0+4+0+16 = 20
Slave 3
ON
6
7
8
1
2
3
4
5
6
7
8
*
Apartment 4
ON
Kit Soul / Art 7W
1
2
3
4
5
6
7
8
manual
Slave 3
ON
6
7
8
1
2
3
4
5
6
7
8
EN