Roof Ventilator TH 500 - 2000
For installation on roof..
NB. Electric installations must be carried out by an authorized electrician.
Flat roof:
(1)
Roof foundation is fastened to the roof.
(2)
Covering (lead or roofing felt) is carried out.
(3)
Connection flange, pipe with counter damper and flexible hose are connected.
(4)
Roof ventilation is fastened to the roof foundation.
Electric Connection
Leads from canopy (marked engine) mounted with extension lead are connected to the
lead from the roof ventilator.
Roof with Slope:
(1)
Roof foundation is fastened to the roof.
(2)
Wings on roof foundation are variable to make them able to follow the slope of
the roof.
(3-4)
Covering (lead, roofing felt or tile) is carried out.
(5)
Connection flange, pipe with counter damper and flexible hose are connected.
(6)
Roof ventilator is fastened to the roof foundation.
Electric Connection
Lead from canopy (marked engine), mounted with extension lead is connected to the lead from
the roof ventilator.
Technical Data:
Type
Connection (V)
Watt expenditure
Quantity of air m
/h v. 0 vs.
3
Rotation speed
Sound level (dB)
Weight in kg
Size of shaft
TH 500
TH 800
230
230
55
140
500
800
2450
2500
50
53
3,8
5,6
Ø160mm
Ø200 mm
TH 1300
TH 2000
230
230
170
255
1100
1700
2400
2480
60
63
11,2
17,2
Ø250 mm
Ø315 mm