Wood Stud Mounting
1.
Locate stud. Verify the center of the stud with an awl or thin nail or
use an edge to edge stud fi nder.
2.
Level the wall plate [01] and mark the hole locations.
3.
Drill pilot holes as illustrated.
4.
Tighten lag bolts [02] only until they are pulled fi rmly against the
wall plate [01].
CAUTION: I
mproper use could reduce the holding power of the lag
bolt. To avoid potential injuries or property damage:
Pilot holes MUST be drilled to a depth of 63.5 mm (2.5 in.), using a
5.5 mm (7/32 in.) diameter drill bit.
DO NOT over-tighten the lag bolts [02].
Any material covering the wall must not exceed 16 mm (5/8 in.).
Minimum wood stud size: common 2 x 4 in. (nominal 1.5 x 3.5 in.)
2
[01]
4
[01]
6902-002009 <00>
13mm
5.5mm
(1/2 in.)
(7/32 in.)
[02]
CAUTION:
1
3
< 16 mm
(5/8 in.)
2
63.5 mm
(2.5 in.)
7