1. Prepare the wall for installation of the wall mount. Use the wall bracket as a template
and mark the holes before drilling the holes.
2. Route the network cable and, if required, the power cable through the wall bracket.
Leave approximately 30 cm (11.8 in) of cable for connecting the camera.
3. If the camera housing has a grounding screw, route a grounding cable through the wall
bracket. Leave approximately 15 cm (5.9 in) of cable for connecting the housing.
4. If connecting an auxiliary device, for example an I/O, audio, or external power device, to
the camera, repeat the step above as applicable to the specific device.
5. Fasten the wall bracket to the wall by tightening the screws.
Attach the Housing to the Wall Mount
NO
NO TICE
NO
TICE
TICE
• Using any other than the provided cable gasket could cause water to seep in and damage
the product. For information about cable gaskets and cable glands that allow for other
cable areas, see www.axis.com
• If more than one cable is used, each cable must be routed through a separate cable gasket.
• Only open a hole in cable gaskets that will be used and if a cable gasket is torn, replace it
with a new cable gasket. Leaving a cable gasket open or using a torn cable gasket could
cause water to seep in and damage the product.
1. Loosen the bottom cover screws and lift the top cover.
2. Loosen the cable cover screws; detach the cable cover from the bottom cover.
3. Remove the cap, the plug and the gasket from the cable gland that is to be used.
4. Remove the grounding screw, washer and grounding shoe ring.
5. Fasten the shoe ring mounted grounding wire and washer with the grounding screw.
14