1.
Safety regulations for the owner / operator
/
The device must only be connected by a qualified electrician.
/
The device may only be opened when de-energized.
/
The device must only be operated on 230 V AC with protective earth.
/
The maximum voltages/currents specified in the technical data must not be exceeded.
/
Only rechargeable batteries of the specified type (6F22) may be used in the device. For
attachment, only the double-sided adhesive surface in the housing cover must be used. The
disposal of the batteries must be done according to the legal regulations.
/
Only the alarm contact switches available as accessories may be used.
2.
Scope of delivery
The FLOW universal alarm system, KBN: FLOWAGU, is used to detect when there is a high water
level by means of an alarm contact switch which is available as an accessory, see page 14.
If the water level exceeds a certain level, the device will sound an audible alarm and switch off the
electrical device connected to the built-in electrical power outlet socket.
In order to provide security against unnoticed overflow, even in the event of a power failure, the
control unit has an emergency power device which can be retrofitted with a NiMH rechargeable
battery, 9-volt block (accessory KBN: Q567228V).
3.
Technical data
Technical data
KBN
Operating voltage
Input
Electrical power outlet socket
Potential-free contact
Protection class
Temperature range (device)
Dimensions
Protection type
Battery (optional, not Included in scope of
delivery)
Noise level of alarm
FLOWAGU
230 V ~ 50 Hz
< 3 W
Max. 16A, 3500 W
Max. 230 V =/~, max. 3 A
I
0 °C – +40 °C
126 mm x 78 mm x 91 mm
IP21
KBN: Q56722BV
95 db
13