5. DMX CONNECTION AND DMX PROTOCOL
DMX addressing
The device is controlled by universal DMX 512 pro-
tocol, DMX address is the start channel used to re-
ceive instructions from the external controller. For
independent control, each fixture must be assigned
its unique address control channels. For example,
this device has four channel modes: 10/13, if we set
the mode at standard 13 channels mode, and there
are several models need to be independently con-
trolled, we just simply address first fixture at 1, and
second fixture at 11, third one at 21, etc.
If the devices have the same address, they will be-
have synchronically.
DMX addressing is limited, don't set the address so
high that without enough control channels for the
fixtures. Display is flashing when no DMX signal is
received.
Fan
Hibe
Back
Flip
User
Code
Cali
CHxx
Ver
load
Auto Speed /High
Speed
OFF, 01M~99M, 15M
02~60m 02m
ON/OFF
Use1/Use2
XXX
XXX
X1.0.0
ON/OFF
This device is equipped with 3-pins DMX in and
out sockets only. Pin 1 = GND | Pin 2 = Signal (-) |
Pin 3 = Signal (+)
The termination is prepared by soldering a 120Ω
resistor between pins 2 and 3.
Fans mode
Sleeping mode
Show backlight time
Display 180°reverse
Users mode
Password: 050
Calibrate channel value
IC Version
Reload Default
English version
- Neo ION 132 F
P. 11