DGFLOW PRESFLO MULTI Manual Del Usuario página 7

Controlador de bomba electrónica
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 11
Installation
Preliminary checks
Take the PRESFLO
out of
®
the packaging and check the
following:
- check for damage,
- check the RATINGS correspond
with those required,
- that the cable bushings and
screws are in place,
- that PRESFLO
's inlets and
®
outlets are clean and free of any
packaging materials,
- that the check valve moves
smoothly.
Hydraulic connections
the joint in two pieces allows ra-
pid connection to the sy-
stem. DO NOT apply se-
alant inside the 2-piece
joint because it already
has an internal o-ring.
Orientation
PRESFLO
can be installed at
®
any angle depending on the flow
direction, as indicated in the
diagrams.
Position
PRESFLO
can either be fitted
®
directly to the pump outlet or
anywhere along the delivery
line. Never install taps between
the pump and PRESFLO
. Do
®
not install a non-return valve
between PRESFLO
®
and the taps,
meanwhile it is possible, although
not necessary, to install a non-
return valve on the suction piping
of the pump.
NOTE 1 - DRY RUNNING = there is no flow and the pressure is lower
than that of the pump start-up pressure (Pm). It occurs when there is no
water. After 15 seconds PRESFLO
message. PRESFLO
AUTOMATICALLY tries to resume NORMAL SERVICE
®
at intervals of increasing time (1, 15, 30, 60 minutes and successively once
every hour - 24 H for AU/NZ - ). If PRESFLO
flow, NORMAL SERVICE is resumed, otherwise, the pump is stopped again
until the next attempt is made. A MANUAL attempt to resume NORMAL
SERVICE can be made at any time.
NOTE 2 - FREQUENT START-UP = the repeated stopping and starting of
the pump at intervals of less than 1 minute from each other. This occurs
when the flow rate is less than 2 litres/min. This may cause damage to the
pump. In event of small leaks (dripping), PRESFLO
guarantees that the pump starts/stops at time intervals of over 1 minute
(less than 60 starts/hour) and that FREQUENT START-UP errors do not occur.
In the event of a major leak or extended use at excessively low flow rates
(less than 2 litres/min), the pump may be started/stopped as often as once
every few seconds, putting the pump at risk of damage. In this case, after
about 40 minutes, PRESFLO
stops the pump for the following 30 minutes
®
(in order to let it cool down) and indicates an ERROR message. If the time
Electrical con-
nections
The electrical
connections
should be made
as indicated in the
diagram which
can also be found
on the inside of
the circuit cover.
Attention! The cable
bushings and circuit board
cover must be properly
assembled and secured
in order to guarantee IP
65 grade protection of the
electrical components.
stops the pump and indicates an ERROR
®
detects any pressure and/or
®
's water accumulator
®
Attention
The pressure applied
by the water column above
PRESFLO
must not exceed that
®
of the pump start-up pressure
(Pm). If, for example, PRESFLO
is installed at a height 20 metres
(65 ft) below that of the highest
tap in the system, the pressure
detected by PRESFLO
approximately 2 bar (30 psi).
A model with Pm = 2.5 – 35 psi
bar should, therefore, be installed
in order to guarantee that the
pump is started when a tap is
turned on.
Attention
The maximum pressure
produced by the pump
must be at least 0.5 bar (7 psi)
higher than the start-up pressure
(Pm). If the pressure produced by
the pump is too low, PRESFLO
will stop the pump and indicate a
'dry running' error message.
Line
Nut
Seal
Cable bushing
interval between the starts-stops is more than 10 seconds (and therefore
poses less of a risk to the pump), PRESFLO
used for more than 30 minutes. Once that enough time has passed to allow
the pump to cool down it is restarted AUTOMATICALLY. The pump may be
restarted MANUALLY any time.
NOTE 3 - OVERCURRENT = electric absorption of the pump (in Ampere)
exceeding the max. allowed (I max). By means of the configuration, it is
possible to set the max. current allowed (I max). During the start-up phase
of the pump PRESFLO
Imax value. If the absorptions remain above the set Imax value, PRESFLO
stops the pump to avoid damaging the motor and signals an anomaly.
PRESFLO
will not automatically restart the pump. The pump may be
®
MANUALLY restarted at any moment. Should the problem persist an anomaly
will again be signalled. The manual restart can be repeated several times
since PRESFLO
NOTE 4 - SHUT-OFF FLOW RATE = Flow rate (Qa) of around 2 litres/min
(0,5 gpm) below which PRESFLO
First start-up
Priming the pump
For instructions on how to
prime (fill) the pump, see the
pump manual.
®
Attention
PRESFLO
check valve: do not use the
will be
PRESFLO
®
pump for priming.
Switching the pump on
The red (Power On) LED lights
up; PRESFLO
instantly detects
that there is no
pressure within the system and
starts the pump
(the green 'Pump
On' LED lights up).
If, within 15 secon-
ds of starting up,
®
PRESFLO
correct priming of
the pump, it stops the pump
and indicates a 'dry running'
error message.
Attention
When the pump is started for
the first time, it may have to
be run for longer in order to
Motor
START button
to restart the
pump and
complete the
priming procedure.
will allow the pump to be
®
allows for a few seconds the current to exceed the
®
does not limit the number of attempts.
®
®
stops the pump.
is fitted with a
®
's outlet to fill the
®
®
does not detect the
®
complete the priming
procedure.
Press the STOP/RE-
®

Publicidad

Tabla de contenido
loading

Productos relacionados para DGFLOW PRESFLO MULTI

Este manual también es adecuado para:

V00103101

Tabla de contenido