1 Operating manual Air Solar 100 Outdoor
These instructions for use provide important information which is helpful for the initial commissioning of the Solar Air 100 Outdoor. Please read these instructions
for use carefully prior to initial commissioning of the solar unit, and store these safely.
Scope of delivery
Solar module with ground spike (1) - Aeration pump with 3 m connection cable (2) - Aeration hose 2 m (3) - Rock bubbler (4)
Article no.
Solar module
Nominal power
Nominal voltage
Rated current
Protection class
Protection type
Temperature range
Safety information
• Do not strike the solar module with the hands, tools or other objects. Damaged solar modules cannot be repaired and must be disposed of in an environmentally-
friendly manner.
• Never open the housing of the device or the parts belonging to it if this is not expressly indicated in the instructions for use.
• This device is suitable for operation at a water temperature of min. 5°C to max. 40°C.
• The device is not suitable for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they
have been supervised or received instructions regarding the use of the device by a person responsible for their safety. Children are to be supervised in order to ensure
that they do not play with the device.
• If the solar module is set up without a module holder, then adequate stability must be ensured in order to prevent damage to the solar module.
• Keep small parts and packaging materials away from children. Hazard due to risk of suffocation!
Intended use
This product is designed exclusively for private use in small garden ponds. Direct solar radiation is required for the operation of the pump. Pond aeration can begin as soon as
the pump and solar module are connected with one another (provided sun radiation is provided). The aeration pump does not have an on/off switch. In order to interrupt the
aeration, the cable connection between the solar module and the pump must be disconnected.
Assembly and initial operation
1. Completely roll out the connection cable on the pump and the aeration hose.
2. Push the aeration hose onto the air output connection pieces of the pump.
3. Push the other end of the hose onto the connection piece on the rock bubbler.
4. Now place the pump at the edge of the pond at a position above the water level
Note: The pump sucks the air in from the underside. Please ensure that both slots on the underside are always kept clear and are not submerged in water.
5. Assemble the module holder (tubes, union nut and ground spike) and attach this to the rear side of the solar module 6. Now connect the plug for the pump with the
socket of the solar module and screw the cap tight. Caution! The plug is protected against polarity reversal, therefore do not apply force when plugging in.
7. Position the solar module in a sunny, shade-free place.
Care and Maintenance
Deposits of dust, dirt and foliage can collect on the solar module. These can be removed using a microfiber cloth and glass cleaner.
Protect the aeration pump against frost!
The aeration pump should be taken out of operation during the cold winter months and the entire system stored in a frost-free location.
2
Guarantee
We give a 2-year guarantee from the date of purchase on materials and manufacturing defects for this product. To make a claim under this guarantee, the original invoice
must be submitted as proof of purchase. Claims brought about by incorrect installation or operation, inadequate maintenance, the effects of frost, inexpert attempts at
repair, the use of force, wrongful acts by a third-party, overloading and foreign objects, as well as all damage to parts resulting from wear and tear, are not covered by this
guarantee. By virtue of the Product Liability Act, we are not liable for damage caused by our equipment, if this is the result of inexpert repairs.
Environmental Protection
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist.
Check with your Local Authority or retailer for recycling advice.
1351374
1,5 W
DC 6 V
260 mA
III
IP65
-30°C to +75°C
Pump
Operating voltage
Operating current
Max. air output
Max. immersion depth
Protection class
Protection type
Operating temperature
Connection cable
DC 6 V
120 mA - 1 W
120 l/h
0.5 m
III
IP44
+5°C to +40°C
3 m