Learning mode:
Only push buttons connected to the Velbus
command can accept up to 7 different push buttons. Memorize he unique address of the module.
Set the module address on:
Address
Learning
F1
OFF: Learning push buttons switching off the relay
E1
ON: Learning push buttons switching on the relay
D1
TGL: Learning push buttons switching the relay on or off
C1
PBM: Learning push buttons activating the set mode on the module
B1
TG1: Learning push buttons starting or stopping the timer
A1
TG2: Learning push buttons starting or stopping the 2nd timer
91
ST1: Learning push buttons starting or restarting the timer
81
ST2: Learning push buttons starting or restarting the 2
The relay will be switched off and the operation mode LED will blink very rapidly to indicate the learning mode. The indication LEDs of
the learned push buttons will also blink very rapidly. In this way it is possible to see which push buttons for the corresponding group have
already been learned. You can add a specific push button by maintaining it pressed until the relay switches on. When releasing the push
button the relay will switch off and the push button indication LED will blink very rapidly as a confirmation. If this does not work then
the maximum amount of push buttons has been reached. To delete a learned push button, maintain it pressed. When releasing the push
button the indication LED will be turned off. You can delete all learned push buttons for a specific control group by maintaining the
manual control on the relay module pressed until the relay switches on. When releasing the manual control push button the relay and the
indication LEDs of all corresponding push buttons will turn off. Repeat the procedure above to learn other commands to the push buttons.
Quit the learning mode by resetting the relay module's original address.
When using firmware version 0736 you will be able to delete all push buttons saved into the memory of the relay module at once. Set the
address to one of the learning addresses. Maintain the manual control on the relay module pressed for 10 seconds. The relay will activate
and deactivate again after 7 seconds to confirm the push buttons have been erased. Set the address back to its original value.
®
via a push button interface or a control panel are appropriate for the procedure below. Each
nd
timer
5