Maintenance

1
Maintaining and Cleaning
the Electronic Automatic
Tank Drain
NOTE: The following maintenance schedule has been
developed for typical application. Maintenance intervals
should be shortened in harsher environments.
Daily
Test the strainer ball valve for proper
operation. Operate the self cleaning
valve if needed.
Monthly
Turn the self cleaning valve to the
open position for 1-2 seconds then
(Every 30 days)
turn to the closed positon.

Troubleshooting

1
Troubleshooting
WARNING: Always turn the compressor OFF, disconnect
from the power source, and drain all pressure from the
system before servicing.
Problem
Valve will not close.
Timer will not activate.
Condensate not discharging.
Troubleshooting
Possible Cause
Debris in self cleaning valve.
Short in electrical component.
No electrical supply.
Clogged port.
Clogged strainer ball valve.
Filter in strainer ball valve could
be clogged.
CAUTION: Always wear ANSI X87.1 approved safety
goggles when performing maintenance. High pressure can
cause injury from flying debris.
To clean the strainer ball valve assembly:
Turn the self cleaning valve to the "OPEN"
position for 1-2 seconds. This will blow out any
debris that may be in the valve.
Turn the self cleaning valve to the "CLOSED"
position.
Solution
Clean valve (See "Maintenance").
Check the power cord for proper connection.
Apply power.
Clean valve (See "Maintenance").
Clean valve (See "Maintenance").
Clean valve (See "Maintenance").
7
Please contact 1-888-HD-HUSKY for further assistance.