ELECTRICAL POWER CONNECTIONS
Single- (230V) and
Three-phase (400V) Motors:
Flashing lamp:
22 23
Power supply:
230V
OPERATING MODES
Automatic / Semiautomatic:
Pedestrian Opening:
Trimmer T3 from 3 to 30s.
It can be activated by any pulse (eg. by remote control) superior to 2s
Hold on switched (Deadman) control:
Led Status Indication:
L1 = 230V 50Hz power supply. Alight
L2 = Photocells, if obstructed light goes off
L3 = Open. Alight whenever an Open pulse is given
L4 = Close. Alight whenever a Close pulse is given
L5 = Stop. It goes off on pulsing Stop
L6 = Radio. It goes on by pressing a transmitter button
L7 = Gate Status; it flashes on gate moving
L8 = Limit switch Close; off when gate is closed
L9 = Limit switch Open; off when gate is open
L10 = It stays on for a time equal to the time set on T4 Trimmer
4138
Drwg. No.
PLUS
SINGLE-/THREE-PHASE FOR SLIDING GATE OPERATORS MEC 200
24
25
M
DIP-SWITCH 4 and 7:
ON: Pre-flashing
OFF: No pre-flashing
230V MAX 25W
4
27
22
28
29
400V
-
+
T2
Dwell Time
from 5 to 128s
-
+
Trimmer
T3
DIP-SWITCH 6
ON= Deadman Control. Dip-switch 4=OFF
and Dip-switch 3=OFF
OFF= Standard Operations
6
26
24
25
26
M
T1 MOTOR RUN TIME
ON: Lamp is not operating during
Dwell Time. Automatic Mode.
OFF: It flashes during Dwell Time .
7
Automatic Mode.
DIP-SWITCH 3
ON= Automatic Closing
OFF= No Automatic. Semi-automatic
3
-
+
-
+
T2 DWELL TIME
from 5 to 150s
OPEN / CLOSE
from 5 to 150s
l'apr ican
cello
closing by pulse
®
7