Notes and instructions with the following symbols require particular attention:
Danger of injury or material damage if this instruction is not complied with
Danger of electrical shock that can result in injury or material damage if this instruction is not complied with
In addition to the basic safety instructions, also comply with the following instructions to prevent accidents:
1. ATTENTION! Before performing any installation or maintenance tasks, disconnect the electrical devices
immersed in the pond from the power source by pulling the plug out of the socket outlet. Do not operate
the pump if there are people in the water. Switch off the main fuse of the main domestic power supply,
before unplugging the mains cable, if the connection plug or the main power outlet are wet. Never
transport or suspend the device by the mains cable.
2. Ensure that the voltage specified on the type plate of the device agrees with the mains voltage.
3. Prior to connecting the device to the mains supply, ensure that the mains cable and the device are not
damaged in any way.
4. The mains cable of the device must form a loop that points downward (DRIP LOOP) to prevent water
from running along the cable and into the socket outlet.
5. The device must have a residual current circuit breaker (RCCB) with a rated residual current of max. 30
mA connected on the line side. Consult a qualified electrician.
6. Do not bury the mains cable in the ground; follow the installation instructions specified in the applicable
local regulations. Consult a qualified electrician.
7. Prior to placing the device in service, ensure that the installation has been properly executed.
8. Install the filter at least 2 meters away from the edge of the pond; ensure that it is attached in such a
manner that it cannot accidentally fall into the water and that the installation area of the filter cannot be
flooded.
9. Do not use or store the device in areas where there is danger of freezing. In winter the device should be
removed, emptied and stored where it is protected against freezing.
10. Do not let the pump run dry (without water flow).
11. Do not use the device with corrosive liquids.
12. The temperature of the pumped liquid must not exceed 35°C (max.) and must not be under 2°C.
1.1.
UVC FILTER
1. ATTENTION! Only use the UVC filter together with the safety transformer included in the scope of
delivery. If there is a defect, the complete UVC unit must be replaced.
2. ATTENTION! This device emits UVC radiation that can harm eyes and skin. Do not use the bulb outside
of the device
3. ATTENTION! NEVER LOOK DIRECTLY INTO THE UVC TUBE WHEN IT IS SWITCHED ON
4. ATTENTION! This device consists partially of glass! Handle with care!
5. The max. temperature of the pumped liquid must not exceed 35°C
6. Never connect the filter to the public water supply network.
7. The UV filter is not designed for immersion in water. If the device should accidentally fall into the water,
do not, under any circumstances, attempt to get it out of the water, until you have pulled the mains plug
out of the mains socket outlet. Also unplug the mains plug if you determine that the exterior of the device
is wet.
8. Do not operate the device with obvious defects.
9. To prevent the lamp from overheating, switch it off when no water is running directly past.
10. Warning. Stop using the UV C sterilizer temporarily during treatment with water and/or fish care products.
1.2.
Pond pump
Mains voltage and current type must agree with the information on the type plate.
x
Install the connection socket outlet in the water-protected area and at least 2 m away from the edge of
x
the pond.
Unplug the mains plug before performing any work on the pump, fountain or pond.
x
Do not operate the pump if there are people in the water (disconnect the pump from the mains supply
x
beforehand!)
Important! If there is damage to the mains cables or the motor housing the complete pump is unusable
x
and must be disposed of. Repair is not possible because the connecting cable is permanently cast in
the motor housing.
Never suspend or transport the pump by the mains cable.