1 1 1 1 . . S S e e t t t t i i n n g g u u p p t t h h e e U U l l t t r r a a V V A A / / 8 8 0 0 0 0 / / 8 8 0 0 0 0 i i
Place the sliding gate operator on the intended surface and unlock the operator
at the unlocking lever.
The Ultra VA / 500i / 800 / 800i must be mounted so that the teeth of the rack
are fully meshed with the teeth of the output pinion. Poor meshing will shorten
the service life and may cause the teeth to skip.
The motor and gear unit is height adjustable by 155 mm. To do this, loosen the
three fastening screws on each side of the support bracket, move the gear unit
with the motor to the appropriate position and fasten it again. Align the Ultra
VA / 500i / 800 / 800i exactly parallel to the door and screw the drive to the
foundation. The operator can still be adjusted through the oblong holes in the
base plate.
1 1 2 2 . . M M o o u u n n t t i i n n g g t t h h e e d d r r i i v v e e
There is a risk of life-threatening / fatal electric shock on contact with the
mains voltage.
SAFETY INSTRUCTION FOR HAZARD AVOIDANCE
x Electrical connections may only be carried out by a qualified electrician.
x When laying the power line, the applicable regulations must be observed
and complied with (IEC 364-4-41).
x Before carrying out any work, disconnect the system from the power
supply. Secure the system against unauthorized restarting of the system.
x Make sure that the on-site electrical installation complies with the
respective protection regulations.
x To avoid hazards, a damaged power supply line must be replaced by a
qualified electrician with an undamaged power supply line.
x Use protective equipment during installation.
x The power supply (usually 230 V) must correspond to the type plate.
DANGER
Fatal electric shock from mains voltage!