RESISTANCE MEASUREMENTS

CAUTION! Switch off power to the device under
test before measuring. Do not test on circuits or
devices where 60VDC or 30VAC is present.
1.
Insert the black test lead banana plug into the
negative (COM) jack. Insert the red test lead banana
plug into the positive (V/Ω) jack. (See Figure 6)
2. Turn the function switch to the Ω position.
3. Use the M button to select the Ω icon on the display
indicating resistance only (without the audible
continuity icon showing).
4. The meter defaults to the auto range mode (
displayed on LCD). Press the R button to access
the manual range mode. Press the R button to step
through the ranges. Press and hold the R button
to return to the auto range mode (
displayed).
5. Touch the test probe tips across the circuit or part
under test. It is best to disconnect one side of the
part under test so the rest of the circuit will not
interfere with the resistance reading.
6. Read the resistance value in the display. The display
will indicate the proper decimal point and value. If
the reading is out of range, the
appear.
PAGE 8 OF 39
OPERATION CONTINUED
Figure 6
Auto
Auto
will be
OL
display icon will

CONTINUITY MEASUREMENTS

1.
Insert the black test lead into the negative COM
terminal and the red test lead into the positive terminal.
2. Set the function switch to the
3. Use the M button to select the continuity mode. Look
for the continuity icon
4. Touch the test probe tips across the wire or circuit
under test.
5. The continuity threshold is between 10Ω and 100Ω.
For measurements below 10Ω the buzzer will always
sound. For measurements above 400Ω, the
always display.

CAPACITANCE MEASUREMENTS

WARNING! To avoid electric shock, remove
power to the circuit under test and discharge
the capacitor under test before measuring.
Do not test on circuits or devices where 60VDC
or 30VAC is present.
1.
Set the function switch to the
2. Insert the black test lead banana plug into the
negative COM jack and the red test lead banana
plug into the positive
3. Press the M button to select the unit of measure symbol F.
4. Touch the test probe tips across the part under test.
5. Read the capacitance value in the display.
6. The display will indicate the proper decimal point
and value.
NOTE: For large values of capacitance, several
seconds may be required before the reading
stabilizes.
position.
on the display.
OL
will
capacitance position.
jack. (See Figure 7)
Figure 7
0621 IH-7095