2
Wall Mounting
2-1: Wood Stud Mounting
CAUTION:
Improper use could reduce the holding power of the lag bolt. To avoid potential injuries or property damage:
Pilot holes MUST be drilled to a depth of 63.5 mm (2.5 in.), using a 5.5 mm (7/32 in.) diameter drill bit.
DO NOT over-tighten the lag bolts [24].
Any material covering the wall must not exceed 16 mm (5/8 in.).
Minimum wood stud size: common 2 x 4 in. (nominal 1.5 x 3.5 in.)
2-2: Solid Concrete and Concrete Block Mounting
CAUTION:
Improper use could reduce the holding power of the lag bolt. To avoid potential injuries or property damage:
Pilot holes MUST be drilled to a depth of 63.5 mm (2.5 in.), using a 13 mm (1/2 in.) diameter drill bit.
Be sure the anchors [26] seat fl ush with the concrete surface.
Mount wall plate directly onto the concrete surface.
Never drill into the mortar between blocks.
DO NOT over-tighten the lag bolts [24].
Minimum solid concrete thickness: 8 in.
Minimum concrete block size: 8 x 8 x 16 in.
12
CAUTION:
6902-002020 <00>