TaoTronics TT-AH008 Manual Del Usuario página 5

Tabla de contenido

Publicidad

1.
ON / OFF: Tap the ON / OFF Button to turn on / off the unit. When
ON/OFF
turned on, the display lights up indicating the current ambient
temperature, and RH value (no water icon will be shown instead if there
is no water). Level 4 MIST VOLUME will be activated. Tap the ON / OFF
Button again to enter standby mode again.
2.
HEATING: Tap the HEATING Button to turn on warm mist and a red
HEATING
heating icon will appear on the display. Tap again to shut off warm mist.
Note: The humidi er will heat the mist, it will take up to 25 minutes for the
mist to warm up. Warm mist can increase mist output by 50 to 100 mL /
hour, but it uses more power than cool mist.
3.
HUMIDITY: Tap the HUMIDITY Button to cycle through the RH level
from 30% to 75%. Once selected, the RH value ashes for 5 seconds. An
"AUTO" icon and the corresponding MIST VOLUME indicator icon will
appear. In this mode, the unit will automatically adjust the mist output
based on the set RH. When the set RH is 1% - 10%, 11% - 15%, or over 15%
higher than the ambient RH, Level 1, 4, or 7 mist volume will be
automatically activated accordingly.
4.
MIST VOLUME: Slide across the MIST VOLUME Buttons to exit
humidity setting and manually cycle through 7 levels of mist output. The
corresponding mist volume indicator icons will appear.
5.
TIMER: Press the TIMER button to set an automatic timer between 1
to 12 hours. The TIMER icon and the set time will appear on the display
and after approx. 5 seconds, the display will show countdown
remaining time by hour. After the timer is set, you can tap the TIMER
Button once to check the current timer setting. Tap and hold the TIMER
Button for 1.5 seconds to exit the timer function.
6.
SLEEP: Tap the SLEEP Button to turn on sleep mode. The display will
dim down to a third of the original brightness. In 15 seconds, all the LED
lights and display will turn off except the sleep icon. The beep sound for
button pushing or no water reminder will be disabled. In sleep mode,
when the ambient RH is at 55% - 70%, Level 2 mist volume will be
All manuals and user guides at all-guides.com
activated; when the ambient RH is below 55%, Level 4 mist volume will be
activated. The unit will stop putting out mist when the ambient RH is higher
than 70% and resume working once it drops to or below 70%. In sleep
mode, you can tap any button to wake up the display. All buttons are
disabled except the SLEEP and ON / OFF Button. You can tap the SLEEP
Button once again to exit sleep mode.
7.
LIGHT: Tap the LIGHT Button to turn on / off the LED light of the water
LIGHT
tank. This function is disabled in standby or sleep mode. Tap and hold
the LIGHT Button for 1.5 seconds can switch between Celsius and
Fahrenheit on the display. The unit is set to Celcius by default for
Europen market and Fahrenehit for the North American market.
The unit comes with a memory function. When the unit is shut off and
power is still connected, it will return to the previous setting when turned
back on.
When water is depleted, the unit will stop working and a no water icon will
appear on the display. It will resume working and return to the previous
setting once water is added in the water tank. The unit will automatically
shut off in 15 minutes after running out of water.
In any mode, once the ambient RH reaches over 90%, the humidi er will
stop working and resume working once it drops below 85%.
The display will dim down in 15 seconds after left alone without any operation.
When water has run out, three beep sounds will be heard. This function is
invalid in sleep mode.
Important
• Make sure water does not over ow when lling the water tank.
• Stop using when the water level is low.
• Do not power on the humidi er when the water tank is not in place.
• Never add water hotter than 40°C / 104°F to avoid any possible damage
or malfunction of the device.
05/06