INSPECTION
When the equipment is received, all items should be carefully checked against the bill of lading to
ensure all crates and cartons have been received. All units should be inspected for concealed
damage by uncrating the units immediately. If any damage is found, it should be reported to the
carrier at once, and a claim should be filed with the carrier. This equipment has been inspected and
tested and has been crated in accordance with transportation rules and guidelines. Manufacturer is
not responsible for freight loss or damage.
INSTALLATION
GENERAL
After the unit crate and base have been removed, locate the legs or casters found in the interior of
the cabinet, if applicable. Legs or casters are optional for this cabinet. Attach the legs or casters to
the unit base by screwing them into the same threaded fittings that were used to secure the crate
base to the cabinet. Insure that the legs or casters are screwed all the way into the base.
LOCATION
The air cooled refrigeration system located on the top of the cabinet requires free air access for
proper operation. Allow a minimum four inch (10.2cm) clearance between the back of the cabinet
and a wall for condenser discharge.
Proper door gasket seal and door alignment are assured when the cabinet is installed on a firm,
level supporting surface. After the cabinet is placed in its permanent location, a cabinet installed
with legs can be leveled by turning the bottom portion of the adjustable legs. Shim material should
be used to level a cabinet that will sit directly on the floor. If casters or legs are not used, it is
required by NSF to seal the cabinet to the floor with an approved sealant such as Dow Corning
#732 silicone.
Examine the door gasket seal by closing the door(s) on a piece of light paper at intervals of
approximately six inches (15.2cm) around the perimeter of each door. When the seal is correct, a
substantial drag should be felt when attempting to remove the paper with the door completely
closed. Each hinge is provided with slotted mounting holes in the wing that is secured to the door.
This feature applies or removes gasket pressure on the hinge side of the door.
If the doors are out of alignment on the cabinet, the doors can be adjusted. This can be
accomplished by opening the door and loosening the screws that hold both the top and bottom
hinges to the cabinet. After adjusting the door so that it is aligned correctly, tighten the screws to
securely hold the hinges in place.
Physical Specifications
Exterior Dimensions
Refrigerant
Width x Depth x Height*
Type/Amount
63-3/8" x 35-1/2" x 64-7/8"
See Serial Tag
(161cm x 90.2cm x 164.8cm)
* Note: Height dimension is without optional legs or casters.
2