INSTALLATION INSPECTION
IS YOUR HOME PRE-PLUMBED?
Your home is pre-plumbed for a water softener/conditioner if you have a loop in the garage or laun-
dry room. Typically, there will be 110 volt outlet within 6 feet of the loop and a ½" drain line stubbed
out of the wall. If your home is pre-plumbed, skip now to Step 1 of Installation Procedures.
TION:
Before starting up system, check water softener drain line to insure that it will drain properly.
IF YOUR HOME IS NOT PRE-PLUMBED
If your home is not pre-plumbed for a water soft-
ener, then we recommend calling for profession-
al installation. If you are attempting to install the
system yourself, you must determine where to
locate the water softening/conditioning system.
The best location depends on several questions:
1. How will you get the water from the water
main to the water softener/conditioner?
2. Where will you run the drain line/waste tube?
(see illustration below)
3. Where is a 110V outlet within 6 feet of the
softener?
Optional: Run a longer wire to most any 110V
waste tube
tubería del desagüe
1-½"
airgap
1½"
trampa
de aire
sink basin
lavabo
Determine the location of your water softener/conditioner, taking into account the above factors, and
determine what materials and tools will be needed for installation. You are now ready to move on to
Step 1 of the Installation Procedures.
INSTALLATION PROCEDURES
WARNING: Do not attempt to remove the red
locking bar (KS5 & KS10 only). The lock-
ing bar is for service only and should only be
removed by a trained softener technician.
STEP 1 CONNECT TO WATER SUPPLY
A. Shut off the main water supply to the house.
Open the hose bib to relieve pressure and
drain out water. Close the hose bib. Place a
bucket or the softener brine tank under the
softener loop to catch the excess water that
will spill out when you cut the pipe. Cut the
plumbing loop off. Determine the inlet side
7 • 02/17 KPWS
4. Do you need to run a hard-water line to
5. Where can the water softener sit on a firm,
1½" airgap
trampa de aire
floor drain
cloaca del desagüe
NOTE: The Air-Check sight glass will NOT have
a rubber ball in it. The air-check on Krystal
Pure™ softeners is located in the brine well in
the brine tank.
loop
caño curvo
outlet.
your outside hose bibs, pool fillers or irriga-
tion system?
fairly level concrete floor or slab?
waste tube
tubería del desagüe
P-trap
trampa-p
of the loop by turning the main water on
very slightly until water comes out of one of
the sides of the loop. This is the inlet supply.
WARNING: You must connect the incom-
ing side of the softener/conditioner to the
inlet supply from the loop. Failure to con-
nect with the proper directional flow can dam-
CAU-
drain source
suministro del desagüe
waste tube
tubería del desagüe
airgap
trampa
de aire
1-½"
1½"