Lubricating Time; Time Storage; Time Setting - Lincoln Quicklub 236-13891-1 Instrucciones De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

User Manual
Operating Instructions
Pause time
determines the frequency of the lubricating times (lubrica-
tion cycles) as long as the machine/ vehicle is in oper ation.
is started and stopped via the machine contact or driving
switch.
is adjustable.

Lubricating time

depends on the system 's lubricant requirement.
is started and stopped via the machine contact or driving
switch.
is adjustable.

Time storage

Time Setting

PCB 4
Cover lid to the control PCB
Page 4 of 20
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Data backup:
The present operating status and the part of the pause time
already lapsed are stored when the machine contac t/ignition
switch is disconnected/switched off.
Reconnection:
When reconnecting the machine contact/ignition switch, the
remaining pause time will continue lapsing from where it had
been interrupted. It will continue lapsing until the pause time
set on the blue rotary switch (see fig. PCB 6) will be reached.
Pause time settings should be adapted to the operating cyc les
required for the respective application (see c hapter "Pause
time s etting", PCB 6).
Data backup:
The present operating status and the part of the lubricating
time already lapsed are stored when the machine contact/
ignition switch is disc onnected/switched off.
Reconnection:
When reconnecting the machine contact/ignition switch, the
remaining lubricating time will continue lapsing from where it
had been interrupted. It will continue lapsing until the lubri-
cating time set on the red rotary switch (see fig. PCB 7) will be
reached.
Lubricating time settings should be adapted to the lubricant
requirement of the respective application (see chapter "Lu-
bricating time setting", PCB 7).
Data backup:
Even if the operating voltage is switched off, the times lapsed
will be stored indefinitely (in the EEPROM).
Reconnection:
When the power supply is switched on again the control unit
continues to operate from the point where it had been inter-
rupted.
To set the pause or lubricating time, remove the cover on
the pump housing.
6001a02
000 02617a
2.6EN-28006-A09
IMPORTANT
Upon completion of the time setting, make
sure to firmly close the cover lid again.
NOTE
To reset a jumper (see fig. PCB 5) remov e
the printed circuit board.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Quicklub 236-13891-2

Tabla de contenido