Utilitech 1/2 HP-C Instrucciones De Instalación página 4

Tabla de contenido

Publicidad

IMPORTANT: SELECT CORRECT VOLTAGE
VOLTAGE SELECTION DIRECTIONS
Disconnect pump from your source
before servicing or handling pump.
Be sure that incoming power supply is
same as voltage selector switch setting.
To change voltage settings slide switch
as shown until desired voltage is visible
on switch.
Be sure switch is completely engaged.
Replace terminal box housing cover and
secure cover with screws.
Do not overtighten screws.
Disconnect pump from power source before changing the pump
voltage. To change the voltage, the selector switch is located
underneath the plastic cover on top of the motor. To access
the switch, remove the eight screws holding the plastic cover.
To change the voltage setting, slide the switch as shown until
desired voltage is visible on the switch. The voltage number that
appears is the voltage setting for the pump. Be sure the switch is
completely engaged. Replace the terminal box cover and secure
the cover with the eight screws.
Wire Selection Guide
PUMP
HORSE
VOLTAGE
MODEL
POWER
3139
115
1/2
3124
230
3121
115
3134
3/4
3105
230
115
3125
1
3114
230
Warning!
MAX WIRE LENGTH IN FEET
NAME-
USING AWG SIZE
PLATE
#14
#12
AMPS
7.1
118
189
3.6
475
756
9.5
100
160
4.7
400
630
84
135
10.2
5.0
339
504
FUSE AND CIRCUIT BREAKER SIZE GUIDE
HORSE-
POWER
1/2
3/4 & 1
*For circuits not over 150 volts to ground.
WIRING YOUR PUMP
Disconnect pump from power before servicing or handling pump.
Remove the cover from the pressure switch. Connect the bare
copper ground to the ground screw in the pressure switch.
Connect the power supply to the 2 open terminals. Turn Big
Spring #1 to raise cut on & off pressure.
Little Spring #2
(Do not touch without
contacting Tech Support)
#10
#8
296
464
1184
1857
250
385
1000
1545
Ground Screw
211
331
Green
845
1327
PIPING
Plastic PVC pipe is shown in the illustrations, but galvanized
steel pipe may be used if desired. All piping must be clean
and free of all foreign matter to prevent clogging. ALL JOINTS
AND CONNECTIONS IN THE WELL ASSEMBLY MUST BE
AIRTIGHT. Even a pinhole leak will prevent the proper operation
of the pump (this is the most common problem). Use thread
compound on all threaded joints unless specified otherwise.
4
LOW PEAK - CART. TYPE
STANDARD LINE
FUSETRON - CART. TYPE
PLUG FUSE*
FUSTAT - PLUG TYPE*
115V
230V
115V
20
10
12
30
15
20
Ground Screw
Green
CIRCUIT BREAKER
230V
115V
230V
6-1/4
20
15
10
30
15
Big Spring #1
20/40
Pressure
Switch
Factory Wires
from Terminal Box
to Pressure Switch

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

3/4 hp-c1 hp-c000312100031140003105

Tabla de contenido