6. Maintenance and inspection
6.1
Safety measures
Important!
i
The operator must provide any protective clothing that may be required.
» Normal maintenance work may be carried out by operational personnel.
6.2
Maintenance and inspection table
Interval
Assembly
Before each
Crane holder
crane operation
Lower section or cover
Missing fastening screws
on the crane holder
As required
Missing fastening screws
on locks
CEMbox outsides
CEMbox insides
Seal in cover
CEMbox
Locks
Monthly
Hinges
Crane holder
Annually
Moving parts
Action
Check screw unions and tighten if necessary.
Bent crane holders must be straightened. Minimum distance to
cover: 25 mm.
A CEMbox with a damaged lower section or cover must be
checked for proper usability by the company CEMO or an
authorised partner and, if necessary, put out of use.
Missing fastening screws must be replaced with M8 x 25 fa-
stening screws in at least grade 8.8 with galvanised hexagon
locking nut and washer.
Missing fastening screws must be replaced with M6 x 15 fa-
stening screws in at least grade 8.8 with galvanised hexagon
locking nut and washer.
Remove adhered dirt by spraying with water or with a damp
cloth.
Remove adhered dirt with a damp cloth.
Treat with a few drops of silicone oil.
Visual check for damage.
Check function, if necessary replace with original spare part
no. 211.4109.023.A2.
Check function, if necessary replace with original spare part
Hinge bolt, no. 211.4409.006
Lock washer, no. 901.4108.000.ZN
Check screw unions and tighten if necessary.
Bent crane holders must be straightened. Minimum distance to
cover: 25 mm.
Lubricate locks and hinges with a few drops of universal oil.
GB