Troubleshooting; Maintenance Schedule - Black and Decker BD 2000i Traducción Del Manual Original

Generador inverter silencioso
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 66

10. Troubleshooting

Fault
Engine does not start
Generator has too little or no
voltage

11. Maintenance schedule

Regular service period
Perform at every indicated
month or operating hour
interval, whichever comes
first.
ITEM
Engine oil
Check level
Change
Air cleaner
Check
Clean
Spark plug
Check-adjust
Replace
Spark arrester
Clean
Valve clearance Check-adjust
Combustion
chamber
Clean
Fuel tank and
filter
Clean
Fuel tube
Check
Remark:
(1) Service more frequently when used in dusty areas.
(2) These items should be serviced by your servicing dealer, Refer to the manual for service
procedures.
Failure to follow this maintenance schedule could result in non-warrantable failures.
Cause
Oil shortage cut-out has not
responded
Spark plug fouled
No fuel
Battery voltage too low
Controller or capacitor defective
Overload cut-off has triggered
Air filter dirty
First
Each
month
use
or
20 Hrs.
O
O
O
After every 300 hrs. (2)
Every 1 year (Replace if necessary) (2)
Remedy
Check oil level, top up engine oil
Clean or replace spark plug
(electrode spacing 0.6 mm)
Refuel / check the petrol cock
Charge the battery
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Clean or replace the filter
Every
Every
3
6
months
months
or
or
50 Hrs.
100 Hrs.
O
O (1)
O
O
O
O (2)
Every
year
or
200 Hrs.
O (2)
13

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

605.800.020

Tabla de contenido