Ref.: EST-083
Walkers
GUARANTEE 6 months since purchase date
EN
Reference
EN
lot no.
EN
Purchase date
EN
Stamp and signature of local
EN
stockist
To validate the warranty your local stockist should indicate the purchase
EN
date.
The manufacturing date is included in the batch number which can be found on the packaging
EN
x
label as
, in the following way: the second and third digits represent the year of manufacture and
the fourth and fifth digits represent the month.
ORLIMAN S. L. U.
C/ Ausias March, 3 - Pol. Ind. La Pobla-L´Eliana
Apdo. de correos 49 · C.P.: 46185
La Pobla de Vallbona Valencia - España (Spain)
Tel.: +34 96 272 57 04 - Fax: +34 96 275 87 00
Tel. Exportación: +34 96 274 23 33
E-mail: orto@orliman.com · Export mail: export@orliman.com
www.orliman.com
EST-083
Fecha de emisión/Date of issue: 2021-02
Fecha de revisión/Revision date: 2021-02 | v.01

USE AND MAINTENANCE INSTRUCTIONS

INSTRUCTIONS FOR USE, STORAGE AND WARRANTY
Dear Customer,
Thank you very much for placing your trust in an Orliman
product. Please read the instructions carefully. Keep these
instructions and the packaging for future reference. If
you have any questions or concerns, please contact your
doctor, orthopaedic specialist or our customer service de-
partment.
ORLIMAN S.L.U. guarantees all its products as long as
the original configuration has not been manipulated or
altered except for the intended use as described in these
instructions.
If the products are used in combination with other prod-
ucts, replacement parts or systems, make sure they are
compatible and made by Orliman
. It does not guarantee
®
any products with altered characteristics due to improper
use, defects or breakage of any kind. To use the warranty,
go to the place where you bought the product as they must
complete the warranty information table on this instruc-
tions sheet. If any serious incidents related to the product
occur, notify Orliman S.L.U. and the corresponding com-
petent authority in your country.
Orliman would like to thank you for choosing this product
and hopes you a speedy recovery.
REGULATIONS
d
This article is defined as a class I medical device. A
Risk Analysis (UNE EN ISO 14971) has been carried out,
minimising the existing risks. Tests have been in accord-
ance with European Regulation UNE-EN ISO 22523 on
Prosthetics and Orthotics.
INDICATIONS
Protection and control following traumatism or surgical
intervention, sprains and ligament injuries, as a method
to replace plaster in the treatment of preulcerous or ulcer-
ous conditions of the foot's plantar surface. Acute plantar
fascitis and in those cases which require a uniform distri-
bution of body weight on the plantar surface and immobi-
lisation of the tibia-tarsus articulation.
FITTING INSTRUCTIONS
For best therapeutic results considering different pathol-
ogies and to extend the useful life of the product, it is es-
sential to choose the correct size for each patient or user.
Excessive compression may be intolerable; adjusting the
compression to be firm yet comfortable is recommended.
If the product must be adapted, any such adjustments
must be done by an orthopaedic specialist or healthcare
professional legally certified to do so who must make sure
the end user or person responsible for fitting the product
properly understands how it works and should be used.
When fitting the product, you must adhere to the
following instructions:
A Adapting the walker to the patient:
Placing the walker in a sitting position and putting a sock
(cotton, if possible) on the patient's leg and foot is rec-
ommended.
1-Separate the rigid structure from the wrap-around
sleeve. Place the wrap-around sleeve snug against the
patient's foot and leg and tighten it as much as possible
using the quick-close system. Position the protective toe
pad. If necessary, place the protective pads in sensitive
areas such as the instep or malleoli.
2-Place the leg over the brace and make sure the foot is in
direct contact with the base and back and that the rigid
structure is centred with the leg and ankle load line.
For Ref.: EST-083, EST-086, EST-087 and EST-088:
3-If necessary, shape the splints for appropriate anatom-
ic adaptation. Remove the protective plastic from the
mediolateral splints to secure them to the wrap-around
sleeve. For Ref. EST-087, secure the tibia protector plate
in the front.
4-Close and adjust the brace with quick-close straps in the
foot area.
5-Close the quick-close straps on the leg. For Ref. EST-083
and EST-086, use the straps for the tibia and calf pro-
tector plates.
6-Check for a correct fit. The product must be firmly ad-
justed yet comfortable.
For Ref.: EST-089 and EST-092:
3-Secure the tibia protector plate to the front.
4-Close and adjust the brace with quick-close straps in the
foot area.
5-Close the quick-close straps on the leg.
6-Check for a correct fit. The product must be firmly ad-
justed yet comfortable.
B Flexion-extension control adjustment (EST-083 and
EST-086):
1-Slide and open the cover to expose the pins.
2-Release the pins, select the desired position and reinsert
the pins. If necessary, first loosen the locking screw to
adjust the flexion-extension.
3-Close the cover by sliding the protective part. To lock the
walker boot at a fixed angle of 90º, position both pins
at 0º. When you wish to lock it in a fixed position at 0º,
7,5º, 15º or 22.5º plantar or dorsiflexion, tighten the
Allen head screws on both joints.
C Using the inflation pump (EST-083, EST-089 and EST-
092):
1-To inflate, turn the valve towards INFLATE (clockwise).
The valve must be really tight so no air is lost.
2-Press the orange circular part several times until you get
the desired pressure.
3-Check for a correct fit. The product must be firmly ad-
justed yet comfortable.
4-To release the air from the bag, turn the valve towards
DEFLATE (counter-clockwise) until comfortable.
p
PRECAUTIONS
Before each use, check that all product components are
present as per the fitting process. Periodically check the
conditions of the product. If you observe any defect or
anomaly, immediately report it to the issuing establish-
ment.
This product is made of inflammable material. Do not
expose the products to situations that could set them on
fire. In the event of a fire, quickly get them off your body
and use the proper resources to extinguish the fire.
To avoid minor discomfort caused by sweating, we rec-
ommend using some type of cotton fabric to separate
the skin from contact with the product material. For dis-
comfort such as chafing, irritation and swelling, remove
the product and see a doctor or orthopaedic specialist.
The product should only be used on healthy skin. It is
not recommended for use over open scars with swell-
ing, redness or hotspots.
l
Products marked with the
symbol contain natural
rubber latex and can cause allergic reactions in people
sensitive to latex.
Products marked with the
(Ref.: EST-083, EST-086,
EST-087, EST-088, EST-089, EST-092) symbol contain
ferromagnetic components and, therefore, extreme
precaution must be taken if you undergo an MRI scan
or are exposed to radiation associated with diagnostic
or therapeutic procedures.
RECOMMENDATIONS-WARNINGS
The use of these products is conditioned by the indica-
tions. Although the product is not defined as a single-use
device, using it on a single patient only is recommended
and only for the intended purposes as described in these
instructions or by a healthcare professional.
When disposing of the product and its packaging, you
must strictly adhere to the legal regulations in your com-
munity.
RECOMMENDATIONS FOR STORAGE AND WASHING
When not using the product, store it in the original pack-
aging in a dry place at room temperature. Stick the Velcro
to each other (if the orthotic device has them), frequent-
ly wash by hand with warm water (30º C max.) and mild
soap. To dry the product, use a dry towel to absorb as
much moisture as possible and let it dry at room temper-
ature. Do not hang it up or iron the product and do not
expose it to direct heat sources such as stoves, dryers, di-
rect sun exposure, etc. When using or cleaning the prod-
uct, do not use abrasive or corrosive substances, alcohol,
ointments or liquid solvents. If not dried off properly, the
detergent residue may irritate the skin and cause the prod-
uct to deteriorate.