Descargar Imprimir esta página

Publicidad

Enlaces rápidos

DAG-001
1
2
ABS Mode
Horizontal Plane
ON/OFF
DIGITAL ANGLE GAUGE
EN
Accurately sets saw blade bevel angle.
Works great for miter saws and table saws.
Automatic LCD backlight
Large display for easy digital reading
Measurements in absolute or relative mode
Angles displayed in degrees
Automatic digit inversion for overhead measurements
Magnetic base
SAFETY FIRST
Always turn off and unplug your power tools before using
your digital angle gauge. Never operate power tools
without blade guards. Instructions below do not show
guards.
INSTRUCTIONS
1. Set gauge on a flat surface such as a table saw, a miter
saw or a jointer table. If you use a band saw, the blade
will be used as the reference surface.
2. Turn on gauge and press ZERO on a surface. Display will
show 0.0° (Fig. 1).
3. Attach gauge to your saw blade or jointer blade. The
magnetic base will keep the gauge in position (Fig. 2).
Make sure gauge is kept perpendicular to the table (Fig.
3).
4. Gauge on properly adjusted tools will display 90°.
Should the reading be off, readjust tool following the
manufacturer's instructions (Fig. 4).
5. Now you can press ZERO to set gauge to 0.0° and measure
the angle of your cutting tool (Fig. 5 and 6).
CALIBRATION
Calibrate gauge in case of accidental falling, damages or
angle faults only.
1. Place gauge on a flat surface, press ON/OFF and ZERO
at the same time until "-1" shows (Fig. 7).
2. Short press ON/OFF. "-1-" should be flashing until "-2-"
shows (Fig. 8).
Imbedded
Keep the gauge perpendicular
Disk Magnets
to the table
3
4
ABS Mode
DIGITAL
ANGLE GAUCE
30°
ZERO
5
6
Relative
Relative
Measuring Mode
Measuring Mode
30°
3. Turn gauge backward 180°, press ON/OFF. "-2-" should
be flashing for a while (Fig. 9).
4. When flashing is over, calibration is completed. Display
shows angles in "ABS" mode (Fig. 10).
LOW VOLTAGE
Replace battery by opening the slot cover on the back-
side of the gauge (Fig. 9).
ON/OFF BUTTON
1. Press ON/OFF once to turn LCD backlight on. Display will
show figures in absolute mode (ABS).
2. Keeping the gauge idle for 10 seconds will cause the
backlight to turn off. To turn it on again, press ON/OFF or
simply move the gauge.
3. Keeping the gauge idle for 5 minutes will cause it to shut
off. Press ON/OFF to turn it on again.
ABSOLUTE AND RELATIVE MEASURING
1. Turn gauge on, press ZERO to set display to 0.0°.
Relative measuring mode is selected.
2. To switch to absolute measuring mode, press ON/OFF
once. When using the absolute measuring mode, the
"ABS" symbol will show on the display.
3. Absolute measuring mode calculates the angle between
the starting flat surface and the end point. Relative
measuring mode calculates the distance between 2
intermediate points (Fig. 11).
TECHNICAL SPECIFICATIONS
Working range: 360° (4x90°)
Resolution: 0.1°
Accuracy: +/- 0.1°
Size: 60x60x25mm (1-3/8"x1-3/8"x1")
Battery: 1 AAA alkaline
DIGITAL
DIGITAL
ANGLE GAUCE
ANGLE GAUCE
7
8
9
ON/OFF
ZERO
ON/OFF
ZERO
ABS Mode
45°
45°
DIGITAL
ANGLE GAUCE
10
ON/OFF
ZERO
11

Publicidad

loading

Resumen de contenidos para CMT DAG-001

  • Página 1 DAG-001 Imbedded Keep the gauge perpendicular Disk Magnets to the table DIGITAL DIGITAL DIGITAL ANGLE GAUCE ANGLE GAUCE ANGLE GAUCE ON/OFF ZERO ON/OFF ZERO ON/OFF ZERO ABS Mode ABS Mode Relative Relative ABS Mode Measuring Mode Measuring Mode DIGITAL ANGLE GAUCE 30°...
  • Página 2 MEDIDOR DE ÁNGULO DIGITAL RAPPORTEUR D'ANGLES DIGITAL Ajuste el ángulo de inclinación de sus sierras circulares Fixez avec précision l’angle d’inclinaison de vos lames circulaires. con precisión. Diseñado para sierras ingletadoras Conçu pour scies à onglet et scies de banc. y sierras de banco.