5.
Determination of filtration
•
Switch both the enlarger and the ColorLi-
ne 100 on
•
Place negative in enlarger, open lens to
maximum aperture, and focus the image
on the enlarger baseboard
•
Swing diffuser under lens
•
Place the ColorLine 100 in the centre of
the baseboard
•
Switch darkroom lights and safelight off
•
Alter both the yellow and magenta filtration
on the enlarger colour head (Cyan = 0)
until both the yellow and magenta LEDs on
the ColorLine 100 are off
•
Switch enlarger light off, swing diffuser
away from the lens, stop the lens down
and expose the print.
•
The exposure time can be determined with
the JOBO Comparator or the JOBO Com-
time. Adjust the lens aperture if necessary
to keep the exposure time within the 2-20
second range. This will prevent colour
shifts due to slope errors.
16
Increase filter values
Reduce filter values