OBSERVEALL LOCAL CODES AND ORDINANCES.
DO NOT, UNDER ANY CIRCUMSTANCES,REMOVE
THE POWERSUPPLY CORD GROUND PRONG.
ELECTRICALGROUND IS REQUIREDONTHIS
APPLIANCE.
For 230/208volt 60 Hz, AC only, 15A fused and
properlygrounded electricalsupply is required.A time
delay fuse or time delay circuit breakeris
recommended.Use a dedicated circuit, sewing only
this appliance.
DO NOT USE AN EXTENSIONCORD,
115V-
RECOMMENDEDGROUNDINGMETHOD
Foryourpersonal s afety,thisappliancemustbe grounded.
This appliance hasa powersupplycordwitha 3-prong
grounding plug.To minimizepossible shockhazard, t he
cordmustbe plugged intoa matinggrounding typewall
receptacle and grounded in accordance withthe National
Electrical C ode(ANSI/NFPA 70) latesteditionand all local
codesandordinances, i f a matingwall receptacle is not
available, i t isthe personal r esponsibility a ndobligationof
thecustomer to havea properlygrounded 3-prongwall
receptacle installed by a qualifiedelectrician.
230V-
Power cord may include a current interrupter
device. A test and reset button is providedon the
plug case. The device should be tested on a
periodic basis by first pressing the TEST button
and then the RESET button. If the TEST button
does not trip or if the RESET button will not stay
engaged, discontinue use of the air conditioner and
contact a qualified service technician.
NOTE: The shape may be different according to its model.
Use Wall Receptacle
Power Supply
Standard 125V,
3-wire grounding
receptacle rated
15A, t 25V AC
Standard 250V,
3-wire grounding
receptacle rated
15A,250V AC
Use 15 AMP, time
delay fuse or 15 AMP,
circuit breaker.
Standard 250V,
3-wire grounding
Use 20 AMP, time
receptacle
rated
delay fuse or 20 AMP,
20A, 250V AC
circuit breaker.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
You can choose between the two methods below according to your preference and window sill shape.
USING
SLIT "A"
Fasten the stopper using Type A screw, and lead the
power cord out through slit "A'L
Screw(Type
A
-4-
USING
SLIT "B"
Fasten the stopper using left screw hole, and rotate
properly to lead the power cord out through slit "B'L