Troubleshooting; Technical Data - Cleco 935382 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 19
4

Troubleshooting

Fault
The green Power LED does not
light up when the power supply
is connected
The red Charge LED does not
light up when the battery is
plugged in
5
Servicing
CAUTION!
To clean the charger, make sure the power plug is disconnected and clean with a dry cloth.
Do not use easily inflammable substances for cleaning.
 To ensure proper charger function, keep the contacts of the charger and batteries free of dirt.
6
Service
If repair is required, send the complete charger to Sales & Service Center. It may only be repaired by autho-
rized technicians. Opening the charger will void the warranty.
7

Technical data

Features
Supply voltage
Power supply frequency
Rated battery voltage
End-of-charge voltage
Idle voltage
Charging current
Protection category
Weight without cable
Ambient temperature during operation
Storage temperature
2069b_1_5_en_bedingt.fm, 28.07.2015
EN
Cause
No power supply voltage
Power cable defective
Charger defective
The battery that is plugged in has
already been charged (red LED
stays off).
The battery contacts are not con-
nected correctly
Contacts are dirty
Battery may be faulty
Data
207 ... 264 VAC ±10%
50 Hz ±5%
26 VDC
29.0 VDC ±1%
Max. 34 VDC
max. 1800 mA ±10%
IP30
0.7 kg
+5°C to +40 °C (+ 32 °F to + 104 °F)
-20 °C to +60 °C (-4 °F to +140 °F)
P1959E/INT 2015-06
Servicing
Measure
Check and restore the power
supply voltage.
Replace power cable.
Replace charger.
Check battery for proper
function.
Plug the battery in again.
Clean the contacts of the
charger and battery.
Check battery and replace if
necessary.
5