The persons carrying pacemaker have to consult a doctor before using these machines.

ACCESSORIES AND CONSUMABLES

Accessories
Consumables
Regularly check the wear condition of the protective tip, nozzle and electrode or in case of significant reduce of the
cutting speed.
It is advised to replace at the same time the nozzle and the electrode.
Tip
(ref. 040182 : plasma 25K / ref.040236 : plasma 31FV)
Replace if cracked or damaged.
Nozzle
(ref.040212 : plasma 31FV / ref.040151 plasma 25K)
Clean if the inside of the nozzle is blocked or dirty.
Replace if the opening is deformed or if the size of the orifice has half increased.
Diffuser
(ref.040175 : plasma 25K ou 31FV)
Replace if lateral orifices are bolcked.
Electrode
(ref.040168: plasma 25K ou 31FV)
To replace: if a significant cavity appears at the electrode center.

TROUBLESHOOTING

Anomalies
The machine delivers no power.
The green working indicator is on.
The thermal protection indicator is
continuously on.
The machine delivers no power.
The green working indicator is on.
The
thermal
protection
blinks 2 times then lights off.
The machine delivers no power.
The green working indicator is on.
The
thermal
protection
blinks quickly.
By pressing the trigger, the air flows
but the pilot arc is not working.
The electrical arc switches off after
about 3 seconds.
If you feel tingling sensation, when
the unit is on and you put your hand
on the welding unit's body.
Plasma 31FV : After having switched
off the plasma (position « O »), the
ventilator and the compressed air
continues to run.
Compass divider kit
040205)
For circular cutting up to
134 cm diameter.
Provided
with
3
magnetic, with center pin,
with thread
Causes
The thermal protection of
the welding unit is on.
The input voltage is higher
than 230V + 15% for plasma
ondicator
25K, 85-265V for plasma
31FV
Torch defect.
indicator
Air supply too weak.
Consumables shabby.
Earth problem.
The
welding
correctly connected to the
earth.
Torch Cooling phase.
(ref.
axes :
Wait until the end of the cooling phase.
Check your electrical network or your
electric generator then switch off and on
your machine.
Check your torch assembly.
Increase the air pressure, then switch off
and on your machine.
Check and change the consumables, then
switch off and on your machine.
Check the earth clamp is well connected to
a clean area (not painted and not fat) of
the part to cut.
unit is
not
Check the plug and the earth of your
electrical network.
Normal behaviour of the machine, wait for
the end of the cooling phase (+/-15 sec).
Trolley
Ref. 040199)
(
For a comfortable use and be
at the advised height
For optimizing the cutting
performances and increase
the nozzles life-time.
Remedies
7