Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

1
INSTALL DOWNDRAFT VENT
A
Two stabilizing brackets must be installed on
each side of the downdraft vent.
• For right-side or straight-down blower
discharge, fasten the stabilizing brackets at
locations A, B, D and E.
• For left-side blower discharge, fasten the
stabilizing brackets at locations B, C, D and E.
4 to 5"
D
A
C
Bottom
Brackets
A
B
Place the downdraft vent into the countertop
cutout so that the back flange of the vent is
sitting on top of the countertop.
C
Secure the screws for the stabilizing brackets
to the cabinet back and side walls.

TOP VIEW

Bracket
Downdraft Vent
D
Confirm the vent system is plumb and square
with the cabinetry.
16
Installation Instructions
Top
Brackets
4 to 5"
E
B
C
Cabinet Back
Wall
Location A
Level
E
Place Cooktop into the countertop cutout.
There should be a 1/8" minimum gap
between the front of the vent trim and the rear
of the cooktop.
F
Connect duct. Use a roof or wall cap (with
damper) that is intended for use with kitchen
hoods and vent systems.
Level
49-80777

Publicidad

loading

Este manual también es adecuado para:

Uvb36 serieUvb36dkbbUvb36skssUvb30skssUvb30Uvb36