21. Do not place any objects on the device.
22. The device can be used only with properly working ventilation.
DEVICE DESCRIPTION (Figure A).
1.Control panel
2.Vertical louvers
3.Horizontal louvers
4.Wheels
5. Plastic containers
6. Inner filter
7. Air inlet cover
8.Water tank
9.Water tank lock
10.Remote control

BEFORE FIRST USE

Installation instructions for casters:
Take out the 4 casters from package. Turn the device upside down on flat surface with soft cloth or mat during assembling to prevent
scratches. Align the caster shaft with the caster installation hole in the body bottom and press firmly to the end. Look at figure C.

USING THE DEVICE

A noticeable reduction in the temperature of the outlet air occurs after putting into the water tank (8) the plastic containers (5) attached
to the product. The plastic containers should be previously frozen in the freezer for few hours. It is recommended to fill the plastic
container (5) with cold tap water and do not exceed MAX level marked on the plastic container. The content of plastic container is
prohibited to edible. Keep away from children.
1. Place the unit on a dry, flat surface.
2. Rotate to flat position the water tank lock (9) and pull out the water tank (8) from the back of the device. Pour clear, cold water, be
careful not to exceed the maximum level. You can pour water w/o pulling out the water tank completely. To remove water tank
completely, first remove the pump by pressing the two end tabs (figure D) and pull out the water tank (8). After water pouring, turn the
water tank lock (9) to horizontal position. Do not tilt the device after pouring the water to water tank. Do not remove water tank while the
device is plug in power supply.
3. Connect the plug to power supply, the device is in standby mode. The power indicator light is illuminated. Now can be used control
panel (1) or remote control (10) to operate the device (figure B). Turn on the device using the "ON/OFF" button (A). The device starts
working in middle speed and switches to low speed after 3 second. Press the button (A) again to switch it back to standby mode.
4. The SPEED button (B) allows you to change the speed of the fan. The following speeds can be selected: HIGH (fast), MIDDLE
(medium) and LOW (slow). The corresponding icons on the panel will light up.
5. COOL button (F) lowers the temperature of the air by running the water pump. Press the button (F) when there is water in water tank
ONLY, Additionally, a set of two plastic containers (5) is attached. Plastic containers (5) should be filled by cold, tap water and do not
exceed maximum level at first. Next, put them on several hours inside the freezer. Then put one or both of containers into water tank (8).
To blow the cool air, the device must be filled with water. When the device is operating, periodically check the water level to see whether
to add water. Press button (F) again to turn off the cold air blowing.
5. The COOL button (F) additionally lowers the air temperature by activating the water pump. Press the button (F) ONLY when there is
water in the water tank. The device is equipped with a set of two plastic containers (5). The plastic containers (5) must be filled with cold
tap water and not exceed the maximum level. Then put them in the freezer for a few hours. Next place one or both of the containers in
the water tank (8). water. While the machine is running, check the water level periodically to see if it needs add some water. Press the
button (F) again to turn off the water pump providing additional cold air blow.
6. Pressing the SWING button (C) starts the oscillation of horizontal louvers (3) that provide even distribution of cold air stream in range
60° in left and right direction. Vertical louvers (2) do not move automatically, so if necessary, manually adjust them to point up or down.
The corresponding indicator turn on.
7. The TIMER button (D) allows for programming the amount of time during which the device will operate before turning itself off
automatically, if the TIMER function is not used, the device will work until it is manually turned off. The turn off time can be set in half-
hour increments from 0,5 to 7,5 hours. There are 4 indicators: 0,5H, 1H, 2H and 4H. For example if the timer is set up for 3 hours, the
1H and 3H indicators turn on.
8. The MODE button (E) allows for changing between one of below tree fan modes NORMAL, NATURAL and SLEEP by repeating
pressing:
- The "NORMAL mode setting up:
"NORMAL" mode operation means blowing on one of chosen speeds:
H: HIGH FAN SPEED,
M: MIDDLE FAN SPEED,
L: LOW FAN SPEED
- The "NATURAL" mode mimics the natural wind action by repeating the fan speed sequence:
When choose the low fan speed: Air flow cycle: L(4seconds) -> M(6seconds) -> stop(2seconds -> L(6seconds -> M(10seconds) ->
L(4seconds) -> M(6seconds) -> stop(2seconds) -> M(2seconds) -> L(4seconds) -> stop(2seconds) -> L(10seconds) -> M(2seconds) ->
stop(4seconds) -> L(2seconds) -> M(6seconds) will be repeated again and again.
When choose the middle fan speed: Air flow cycle: M(6seconds) -> H(2seconds) -> L(6seconds -> M(8seconds) -> H(4seconds) ->
L(2seconds) -> M(10seconds) -> L(6seconds) -> M(8seconds) -> H(2seconds) -> stop(2seconds) -> H(4seconds) -> L(8seconds) ->