In-Wall
Digital Timer
Specifications:
120VAC 60 Hz
15A General/Resistive
1200W Tungsten
1200VA Ballast
1/2 HP
Installation Instructions
If you are unsure about the installation of this timer please contact a licensed electrician.
1. Turn power off at circuit breaker or fuse box before installation.
2. Remove current wallplate and switch from wall box.
3. Wires should be stripped to 5/8". (16mm).
4. Remove timer from package. Look at the back of the timer and
you will see LINE, LOAD, NEUTRAL and GROUND.
5. Loosen the LINE and LOAD screws with either a flat-blade or
Phillips screwdriver. When loosening terminal screws, stop when
you feel resistance. NOTE: Do not remove terminal screws.
6. Insert the line side wire from the wire box into hole marked LINE
and tighten the LINE screw.
7. Insert the load side wire from the wire box into hole marked
LOAD and tighten the LOAD screw.
8. Attach ground wire from box to the ground lug on the timer.
9. Remove white jumper wire from the package. Insert and tighten
jumper wire into the hole marked NEUTRAL.
10. Connect the neutral wire from the timer to the neutral wire in the
box. Often the neutral wire (white) can be found in the back of the
wire box connected with a wire nut. There may be several neutral
wires bound together. Add the neutral wire to all neutral wires
bound together and retighten the wire nut, making sure that the
wire nut is tight.
11. Tug each wire to verify connection, retighten if needed.
NOTE: Be sure that all wires and wire nuts are secure.
12. Insert timer into the 2 1/2" wall box, being careful not to pinch
any wires. Be sure the TOP (indicated on yoke of timer) is facing
up. Fasten the timer to the wall box using the screws provided.
13. Place rocker/decorator wallplate on timer, being careful to not
overtighten wallplate screws.
14. Turn the power on at the circuit breaker or fuse box.
Works with dimmable
LED and CFL bulbs.
26893 WIRING VERSION 02
06/15/17
MADE IN CHINA
GE is trademark of General Electric Company and is under license by Jasco
Products Company LLC, 10 E. Memorial Rd., Oklahoma City, OK 73114.
This Jasco product comes with a 1-year limited warranty. Visit
www.byjasco.com for warranty details product registration.
Questions? Contact us at 1-800-654-8483 between 7:00AM–8:00PM CST.
This device complies with part 15 of the FCC and Industry Canada license-exempt RSS standard(s). Operation
is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized
modifications to this equipment. Such modifications could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help
Important note: To comply with the FCC RF exposure compliance requirements, no change to the antenna or the
device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure
requirements and void user's authority to operate the device.
CAN ICES-3(B)/NMB-3(B)
• For supply connections use 14
AWG or larger wires suitable and
rated for at least 75ºC
• For grounding lead use 12 AWG
or larger wires suitable and
rated for at least 75ºC
• Tighten wire connections to
12.4lbf-in. (1.4Nm)
• Use copper wire only
Typical SPST Installation
Figure 1
Black
TOP
Load
LOAD
Black
Line
LINE
NEUTRAL
GROUND
Green
Ground
JUMPER WIRE
White
Neutral
= Wiring Nut
Black
Line
NO
120 VAC
Power
Load
C
Source
White
RISK OF ELECTRIC SHOCK
• SHUT OFF POWER AT FUSE BOX OR CIRCUIT
BREAKER BEFORE INSTALLATION
• DO NOT USE IN WET LOCATIONS
• USE INDOORS ONLY
RISK OF FIRE
•DO NOT USE TO CONTROL APPLIANCES THAT
CONTAIN HEATING ELEMENTS (COOKING
APPLIANCES, HEATERS, IRONS, ETC.)
• DO NOT EXCEED ELECTRICAL RATINGS
• USE COPPER WIRE ONLY WITH THIS DEVICE
• DO NOT USE TO CONTROL RECEPTACLES
Black
Black
Light
White
WARNING