8- Multifunction Output Relays and Output Signal
Operation
Function
Description
Code no.
Analogue Output
Voltage Mode
8-00
(0 to 10 VDC, Term.
FM+)
Analogue Output
8-01
Gain (%)
Output Relay R1
8-02
Operation Mode
Output Relay R2
8-03
Operation Mode
Frequency Reached
(Hz)
8-04
(Refer to 8-02:
0001)
Frequency Reached
8-05
Bandwidth (±Hz)
Emotron AB 01-3990-11r3
Range/Code
0000: Output Frequency
0001: Frequency Setting
0002: Output Voltage
0003: DC Voltage
0004: Output Current
0005: PID Feedback *7
0 to 200
0000: Run
0001: Frequency Reached
(Frequency Command) (Set
Frequency ±8-05)
0002: Set Frequency (8-04 ±8-05)
0003: Frequency Threshold Level
(>8-04) - Frequency Reached
0004: Frequency Threshold Level
(<8-04) - Frequency Reached
0005: Over torque Threshold Level
0006: Fault
0007: Auto Restart
0008: Momentary AC Power Loss
0009: Emergency Stop Mode
0010: Coast-to-Stop Mode
0011: Motor Overload Protection
0012: Drive Overload Protection
0013: PID Feedback Signal Loss
0014: PLC Operation
0015: Power On *7
0.00 to 650.00
0.00 to 30.00
Factory
Re-
setting
marks
0000
*1
100
*1
0006
0000
0.00
*1
2.00
*1
Software index