Provision For Emergency Drainage; Non-Return Valve; Interception Gate Valve - DAB FEKABOX 200 Instrucciones Para La Instalación Y El Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 93

5.8 Provision for emergency drainage

On the rear, at the base of the station, is a connection for an emergency drainage system, marked by the
symbol
. You can use the connection to attach a secondary pump (for example a manual diaphragm
pump), the discharge pipe of which must be independent from that of the internal electropump in the station.
Identify the seat for the duct on the bottom of the station, open the duct and connect the emergency drainage
pipe. Check that the coupling is watertight.

5.9 Non-return valve

Install a non-return valve in the pipe connecting to the public/private sewer network. This will avoid the reflux
of liquid. Place the valve at a distance of at least 1 metre from the lifting station to allow the flow of liquid,
moved by the pump, to open the shutter of the valve (unless indicated otherwise by the manufacturer).
Always refer to the local and/or national regulations, laws and standards in force.
The non-return valves are available as accessory kits.
5.10

Interception gate valve

Install an interception valve in both the inlet pipe and the delivery pipe (connection to the public/private sewer
network). In this way maintenance work can be carried out without having to drain the whole system. Gate
valves or ball valves may be used.
The interception valves are available as accessory kits.
See example of installation in chapter 4.
ENGLISH
44

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fekafos 280Fekafos 280 doubleFekafos 550 double

Tabla de contenido