AEG CLR215 Manual Original página 11

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 42
3
CHECKING THE LEVEL ACCURACY OF THE VERTICAL
BEAM
1. Hang an approximately 4 m plumb
line on a wall.
2. After the plumb line has settled, mark
point a1 on the wall, behind the
plumb line, near the plumb cone.
3. Set up the cross laser on a tripod or
on a fl at surface in front of the wall at
a distance of approximately 2 m.
4. Switch ON the self-leveling mode,
and press the button to project the
vertical beam towards the plumb line.
5. Turn the laser so that the vertical
beam will merge with the plumb line
below the hanging point.
6. Mark point a2 on the wall, in the
middle of the vertical beam at the
same height as a1.
7. The distance between a1 and a2,
should be no more than
1.5 mm for CLR215
1.6 mm for CLG220.
ENGLISH
a1
a2
a1
10

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Clg220

Tabla de contenido