Boiler Cleaning; Electric Diagram - Fasa NPX Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 49
EN
CHECKING THE WATER INTAKE FILTER
Inspect and clean the water intake filter on the in-
take union periodically. This is important to prevent
fouling which may impair operation of the pump.
CLEANING THE FUEL FILTER
Check the fuel filter periodically and replace if it has
deteriorated or is excessively dirty.
DESCALING
The descaling procedure must be carried out periodically
with specific products. The interval depends on the hard-
ness of the water. Pour one litre of product for every 15
litres of water into a drum containing at least 30 litres of
water. Disconnect the gun from the high pressure line and
place its free end in the drum, in order to form a closed cir-
cuit, and draw the solution into the machine for at least 10
minutes. The delivery end of the line should discharge into
a canvas or mesh bag so that the scale removed is not re-
turned to the circuit. Then restore the normal connection
and rinse with plenty of cold water. This operation should
be carried out by our after-sales service, since the descal-
ing product may cause wear of components. Comply with
the regulations in force when disposing of the descaling
agent.
Liquid softener tank integrated
(Optional - if included)
The descaling procedure must be carried out pe-
riodically with specific products. The interval de-
pends on the hardness of the water. This opera-
tion should be carried out by our after-sales serv-
ice, since the descaling product may cause wear
of components. Comply with the regulations in
force when disposing of the descaling agent.
- Fill the softener tank with our products (in
all cases, with non corrosive products). The
dispensing rate is set at a medium value; the
After Sales Services will be able to adapt the
setting to local conditions.

BOILER CLEANING

• WARNING: For all maintenance of the boiler, of the
high pressure pump and of the machine, it is necessary
to address to qualified personnel or to an authorized
assistance center.
The boiler cleaning must be periodically executed every
180 ÷ 200 hours of working proceeding as follows:
- Carefully remove the nozzle holder flange and
the electrodes holder (boiler head).
- Clean with compressed air the nozzle filter and
26
check the electrodes position.
- Remove the boiler cap, clean the deflector.
- Manually take away the interior cap.
- Unscrewing the locking nuts and take the
boiler coil out.
- Clean the coil by an iron brush.
- Suck the residuums from the boiler.
- Replace every parts doing the operations in the
inverse way.
• WARNING: The general checking and combustion
regulation must be periodically executed by specialized
personnel as prescribed by the law.

ELECTRIC DIAGRAM

See illustrations, page 7-8.
WATER DIAGRAM
See illustrations, page 7-8.
> REPAIRS - SPARE PARTS
For any problems not mentioned in this manual, or if
the machine breaks down, you are urged to contact
an Authorized After-Sales Service for the relative
repair or for any replacement of components with
original spare parts. Use exclusively original replace-
ment parts.
> WARRANTY CONDITIONS
All our machines are subjected to strict tests and are
covered against manufacturing defects in accordance
with applicable regulations (minimum 12 months). The
warranty is effective from the date of purchase. If your
high pressure washer or accessories are handed in for
repair, a copy of the receipt must be enclosed.
Guarantee repairs are being made on the following
conditions: - That defects are attributable to flaws or
defects in materials or workmanship. - That the direc-
tions of this instruction manual have been thoroughly
observed. - That repair has not been carried out or at-
tempted by other than authorized service staff. - That
only original accessories have been applied. - That the
product has not been exposed to abuse such as knocks,
bumps or frost. - That only water without any impuri-
ties has been used. - That the high pressure washer has
not been used for rental nor used commercially in any
other way.
The following are not included in the warranty: -
Parts subject to normal wear. - The high-pressure tube
and optional accessories. - Accidental damage, caused
by transport, neglect or inadequate treatment, incor-
rect or improper use and installation failing to comply
with the indications in the instruction manual. - The
warranty shall not cover any cleaning operations to