OPERATING FROM THE CONTROL PANEL
TURNING THE APPLIANCE ON/OFF
Note: Never turn off the air conditioner by simply pulling the
key in order to put your air conditioner in
plug. Touch the
stand-by and wait a few minutes before pulling the plug. In this
manner, the appliance can perform operating status checks.
MODE SELECTION
AIR CONDITIONING MODE
This is ideal for hot and humid weather
when the room needs to be both cooled
and dehumidified.
To correctly set this mode:
• Touch repeatedly the MODE key until
the air conditioning symbol appears.
The display will show the symbol
• To change to the desired tem-
perature, touch the
Note: The most suitable temperatures,
during the summer range from 75 to
81°F. However, setting the temperature
significantly lower than the outdoor
Before plugging in the appli-
ance, check the caps on back of
the unit are correctly inserted
on drainage hose A11 and A13.
Insert the plug in the socket.
Two dashes appear on the display
indicating that the appliance is in
stand-by. Touch the
to turn on the appliance. When
the appliance comes on, the last
function set before it was shut off
is activated.
NOTE: After a few seconds of inac-
tivity, the brightness of the control
panel will be automatically reduced
and in the next few minutes it will
be further reduced. To turn the ap-
pliance off, touch the
To select the desired operating
mode, touch repeatedly the
MODE key until the desired func-
tion is selected.
or
temperature is not recommended. In conditioning mode, the
air flow can be selected only from the remote control.
DEHUMIDIFYING MODE
(C1) key
the appliance to allow the humidity to be discharged outside.
To correctly set this mode:
Touch repeatedly the MODE key until the dehumidifying
•
symbol
•
The appliance automatically chooses the best air flow.
Note:
In case of high ambient humidity, it is possible to drain the
condensation continuously by applying the tube supplied B13
to the upper drainage hose A13 (fig. 7) and thus allowing the
key.
water to flow into a container.
Unscrew the cap by following the directions and inserting the
tube. Pay attention that water does not overflow onto the floor
(fig. 8). If the connector is not in use, to avoid overflow onto
the floor, remember to screw the cap back into place and the
drainage hose is not obstructed.
.
key.
9
This is ideal for reducing humidity
in the room (spring and autumn,
damp rooms, rainy periods, etc).
For this type of use, the appliance
must be set up same as in the air
conditioner mode. That is, the air
exhaust hose B4 must be fitted to
appears.
yes
no
7
8