INSTALLATION INSTRUCTIONS
TradeMaster
FAN SPEED CONTROLS
R E A D A N D S A V E T H E S E I N S T R U C T I O N S !
To be installed by a certified electrician or other qualified person.
WARNING – To prevent severe shock or electrocution, always turn power OFF at
the service panel before installing this unit, working on the circuit, or changing a
lamp.
CAUTION – To reduce the risk of overheating and possible damage to
other equipment, do not install to control a receptacle, a fluorescent light,
or a transformer-supplied appliance. Use this control only with fans that are
marked as suitable for use with solid-state fan speed controls.
Any number of fans may be controlled by a single fan speed control provided
the sum amperage rating of the fans does not exceed the amperage rating of
the fan control.
Do not connect fan control to power source other than 120VAC, 60 Hz only.
Use copper wire only.
DIRECTIONS
1. Disconnect power to circuit at the panel by removing fuse or turning circuit
breakers OFF before installing.
2. Remove wall plate and switch mounting screws, pull existing switch from
wall box.
3. Disconnect existing switch from circuit.
4. Connect fan speed control as shown in the installation diagram using #12 or
#14 AWG stranded or solid copper conductors. Strip wire using gauge on
back of device.
5. Install fan speed control in wall box, with word 'TOP' on the strap right side
up, using mounting screws provided.
6. Restore power. To change the minimum speed DISCONNECT POWER
FROM CIRCUIT. Remove fan speed control from wall box. Use a small,
insulated, flat-tipped screwdriver to adjust trim pot located through access
opening on ground side of control. After adjusting, remount fan speed
control in wall box per above instructions. Restore power and test. Repeat
above as necessary. Disconnect power again when adjustment is complete.
NOTE: Never adjust trim pot when circuit is live.
7. Attach wall plate, then restore power to circuit.
NOTE: It is necessary to remove knob on Short Slide version before
attaching wall plate.
8. Attach wall plate.
NOTE: A 0.5A minimum load is required. It is normal for the control to feel
warm during operation. Use a separate neutral wire for each phase of a
multiphase system containing a dimmer, and for high power single phase
applications where flickering is present.
Toggle
®
Decorator Slide
Short Slide
FAN SPEED CONTROL TYPES
INSTALLATION DIAGRAM FOR SPEED CONTROLS (wiring is same with
each of the fan speed control types)
MULTIPLE GANGING OF DIMMERS & OTHER DEVICES
Any combination of fan control models and other devices may be ganged
together. Fan controls can be ganged without removing fins. De-rate the
maximum load according to the following table.
MAXIMUM
RATED LOAD
2 CONTROLS
5A
WARRANTIES
Lifetime Warranty. The device you have purchased is warranted under normal
use against defects in workmanship and materials for as long as you own the
device. If the device fails due to manufacturing defect during normal use, return
the device for replacement to the store where purchased or send to:
Pass & Seymour Legrand
50 Boyd Avenue
Syracuse, NY 13209
All requests for replacement must include a dated sales receipt (legible copies
acceptable).
ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO ANY
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, ARE LIMITED TO A PERIOD OF TWO YEARS FROM THE
DATE OF PURCHASE. YOUR SOLE AND EXCLUSIVE REMEDY AGAINST
PASS & SEYMOUR LEGRAND UNDER ANY WARRANTY SHALL BE THE
EQUIVALENT REPLACEMENT OF THE DEVICE. IN NO EVENT SHALL ANY
WARRANTY APPLY TO ANY DEFECT ARISING OUT OF ANY ALTERATION
OF THE DEVICE, IMPROPER WIRING, IMPROPER INSTALLATION,
MISUSE, ABNORMAL USE OR NEGLIGENCE. IN NO EVENT SHALL PASS &
SEYMOUR LEGRAND BE LIABLE FOR LOST PROFITS, INDIRECT, SPECIAL,
EXEMPLARY, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states
do not allow limitations on how long implied warranties last and do not allow
exclusion or limitation of incidental or consequential damages. Some of the
above limitations or exclusions may not apply to every purchaser.
GANG REDUCTION
3+ CONTROLS
4A
3A

Publicidad

loading

Resumen de contenidos para LEGRAND pass & seymour TradeMaster LS Serie

  • Página 1 PURPOSE, ARE LIMITED TO A PERIOD OF TWO YEARS FROM THE DATE OF PURCHASE. YOUR SOLE AND EXCLUSIVE REMEDY AGAINST PASS & SEYMOUR LEGRAND UNDER ANY WARRANTY SHALL BE THE EQUIVALENT REPLACEMENT OF THE DEVICE. IN NO EVENT SHALL ANY...
  • Página 2 7. Fije la chapa de pared, entonces restáurele la corriente al circuito. NOTA: donde fue adquirido o envíelo a: Pass & Seymour Legrand, 50 Boyd Avenue, Es necesario quitarle la perilla en la versión de Deslice Corto antes de fijar Syracuse, NY 13209 la chapa de pared.
  • Página 3 échéant, là où vous l’avez acheté ou l’envoyer 8. Mettre en place la plaque murale. à: Pass & Seymour Legrand, 50 Boyd Avenue, Syracuse, NY 13209 REMARQUE: Une charge minimale de 0.5 A est requise. Il est normal que Toute demande de remplacement doit contenir un reçu de vente...
  • Página 4 Part No. 340437 Rev. B Printed in U.S.A. © 1997 Pass & Seymour/Legrand, P.O. Box 4822, Syracuse, NY 13221, (800) 223-4185...

Este manual también es adecuado para:

Pass & seymour trademaster lssc5Pass & seymour trademaster lssc5wPass & seymour trademaster lssc5pw