General Installation Instructions

Joint connection

Coping with condensation

Appliance connection (female appliance top)

Condensate drain

Annually inspect the collector and trap for obstructions and fluid content in the trap.
Drain and dispose of condensate per local codes.
Remove the drain cap and install a condensate trap per the installation instructions.
5
x
B
D
C
Vent connections must be firmly pressed
together so that the gaskets form an
airtight seal. To ensure optimum joint con-
nection, it is recommended to secure with
three #8x1/2" self tapping screws. Secure
the vent to the wall or ceiling with pipe
clamps or perforated hanger iron.
Vent connections extending beyond the
outside of a building or structure should
be enclosed to protect seals and gaskets.
Horizontal vent lengths greater than 5ft.
(1,5m) should pitch a minimum 1/4"/ft.
(25mm/m) or (1°) to the appliance.
NOTE
See exception under Condensate on
page 3.
Installations with a female appliance top
do not need an appliance adapter. Simply
insert the male end of a vent component
into the female appliance top.
NOTE
The molded line on the male end of
the elbow (x) indicates the proper
insertion depth into the appliance top.
Condensate can damage the water
heater, please read carefully page 3
in this installation manual.
To prevent condensate from draining
back to the appliance, a condensate
collector (B) and trap (C) should be
used. The trap must maintain 3" (75 mm)
of fluid and the drain tube must pitch
down from the appliance.