4. Assembly and connection of the cable connection terminal VHM/KV1
(Art. No. 79609)
e
P
e
M
Install vertically in the middle section M of the housing.
P, e
The cable connection terminal circuit board P is screwed to the studs using the
enclosed self-tapping screws e (including washers) as shown in the diagram.
Instructions When wiring ensure that the power lines L1 and N are attached to the terminals
provided for them. The earthed wires are supported on the terminals.
Instructions When connecting and operating the heater and camera, ensure that the operating
voltages are the same and the power consumption is permissible.
The heater's starting current may be more than 10 times the nominal current.
, VHM/KVS2
(Art. No. 79612)
P E
9
1 0
1 1
M
and VHM/KV2
(Art. No. 79627)