EN
iSLS8 – Interface compatible with Solius
Thermostat 485 Bus
Features:
•
Interfaces with Solius 485 Bus.
•
MdiBus interface.
•
DIN Rail Distribution Board mounting.
Applications:
•
Control of up to 8 thermostats.
Specifications:
Power supply Voltage: 15VDC;
Consumption: 30mA @ 15VDC;
485 Bus max. common mode Voltage: -7 ~ +12VDC.
Storage Temperature: -10ºC to 60ºC;
Operating Temperature: 10ºC to 50ºC;
Maximum humidity: 80% non-condensing;
Physical Specifications:
Dimensions: 52mm x 90mm x 70mm, mounting on DIN rail (3
modules);
Protection degree: IP20, for indoor use;
Self-extinguishing plastic box UL-94 V0;
Compatibility:
Compatibility with iThink module: FW V1.45 or higher.
Compatibility with Mordomus software: Mordomus iThink
V2021 or higher.
Compatibility with Solius Thermostats: 802, 804, 812 and 814.
ATTENTION:
Never open the housing.
Never remove the circuit board from its housing.
Never crimp or cut cables while they are connected
to powered equipment.
The module is not provided with additional protection
against short circuit, therefore it is recommended to
use a power supply with the correct specifications.
Mordomus shall not be liable for any damages
resulting from the use of our equipment outside the
specifications and/or for a purpose other than that
intended.
When using a low cross section cable there might be
voltage drops that could force the module into under-
voltage protection mode.
Do not connect power supplies with an output current
greater than 4A.
The power supply shall never be connected to the
modules at the extremities of the bus as in
Do not connect more than 8 thermostats on the 485
Bus.
Avoid contact between the conductors of the 485 bus
iSLS8
and any other voltages.
The Mordomus power supply shall be connected to a
central module in order to distribute the power to the
remaining modules. For larger installations add as
many power supplies as required, always respecting
a uniform distribution. View
Overview:
MdiBus In connector
MdiBus Out connector
Power Supply iPSE154 (15V 4A)
Addressing Button
Power supply connector 15VDC 2,1x5,5mm
485 Bus connector
Connections:
Specification and cross section of conductors:
MDiBus Circuit - CAT 6 UTP;
MDiBus connection: To connect the module to the MDiBus a CAT
6 UTP cable with RJ45 connectors according to EIA568A or
EIA568B standards must be used.
15VDC Power supply: It is recommended to use the iPSE154
power supply. The iSLS8 module can source its power from other
nearby modules through the MDiBus cable.
485 Bus: It is recommended to use one twisted pair of UTP cable
for the 485 bus connections. For best performance the network
should be arranged in bus topology. It is advised to avoid routing
the bus conductors adjacent to any mains power conductors. Avoid
contact between the 485 bus and any other signals and voltages.
Enrollment:
To enroll the iSLS8 module proceed as follows:
1.
Make sure that the iSLS8 is powered by a suitable
power supply
and connected to the MdiBus
.
2.
In the Mordomus software access the menu
Configurations
and
Modules/Addresses.
3.
On the iSLS8, press and hold the addressing button
figure
2.
for at least 1sec. The green LED will blink slowly
until the addressing is complete.
4.
The iSLS8 should be added automatically to the list
HW 1.0
and the green LED should stop blinking.
Note: After enrolling, by default all thermostats are disabled in the
Mordomus software. Please enable the number of thermostats that
are present in the installation.
Figure
3.
Thermostat Modbus ID:
The thermostats connected to the iSLS8 must have their Modbus
IDs set from [1-8]. Do not assign the same ID to more than one
thermostat. In order to assign the Modbus ID of each thermostat
proceed as described in the part 4.3 of the user manual of the
thermostat.
Reset:
To perform a reset to the module, interrupt the 15VDC
power supply for 5 seconds.
LED codes:
Green LED ON: Module powered and enrolled to software;
Red LED ON: Module powered and not enrolled to software;
Green and Red LEDs blinking simultaneously: Under-voltage
protection mode. Power supply voltage is to low;
Green LED blinking continuously: Module awaiting address
definition;
Red LED flashing: Module sending/receiving data.
Note: The light of the green and red LEDs is visible through the
grid of the plastic enclosure.
This product complies with the Electromagnetic
Compatibility Directive 2014/30/EU.
This product conforms with the EU Directive 2011/65,
RoHS
regarding the restriction of use of certain hazardous
substances in electric and electronic devices.
For EU countries only.
All old electrical and electronic devices must be
separated from normal household waste and disposed
of at designated facilities. For further information
contact your local authorities, waste disposal office or
the shop where you bought the device.
-----------------------------------Disclaimer---------------------------------------
All product names, logos, and brands are property of their
respective owners.
http://mordomus.com/mordomus/docs/ithink/i SLS8 .pdf
access
the
sub-menu
PT
iSLS8 – Interface compatível com Bus
485 de Termostatos Solius
Caraterísticas:
•
•
•
Aplicações:
•
Especificações:
Tensão Alimentação: 15VDC;
Consumo: 30mA @ 15VDC;
Tensão modo comum máx. Bus 485: -7 ~+12VDC.
Temperatura Armazenamento: -10ºC a 60ºC;
Temperatura Funcionamento: 10ºC a 50ºC;
Humidade máxima: 80%, sem condensação;
Especificações Físicas:
Dimensão: 52mm x 90mm x 70mm, fixação em calha DIN (3
Módulos);
Grau de Proteção: IP20, para uso no interior.
Caixa em plástico auto extinguível UL-94 V0;
Compatibilidade:
Compatibilidade com o módulo iThink: FW V1.45 ou superior.
Compatibilidade com Software Mordomus: Mordomus iThink
V2020.1 ou superior.
Compatibilidade com Termostatos Solius: 802, 804, 812 e 814.
ATENÇÃO:
v.2113
Interligação com bus 485 Solius.
Interface MdiBus;
Montagem em calha DIN.
Controlo de até 8 termostatos.
Nunca abrir a caixa de suporte de calha DIN.
Nunca remover a placa de circuito impresso da
caixa.
Nunca cravar fichas ou cortar os cabos enquanto
estes
estiverem
conectados
a
equipamentos
alimentados.
Os módulos não são providos de proteção adicional
contra curto circuito, recomenda-se por isso o uso de
fontes de alimentação com as especificações
corretas.
A Mordomus não se responsabiliza por quaisquer
danos resultantes do uso dos nossos equipamentos
fora das especificações e/ou para uma finalidade
diferente da prevista.
O uso de cabo de baixa secção provoca quedas de
tensão o que poderá ativar a proteção de subtensão
do módulo.
Nunca conectar fontes de alimentação com saída
superior a 4A.
A fonte de alimentação nunca deverá ser conectada
2/4