CP 4123, CP 4125
Too much lubrication can cause starting problems,
low power or uneven performance.
Use a synthetic lubricant such as CP Airolene Plus
Tool Oil or mineral oil with the properties
recommended in the table below.
Temperature
Lubricant
range °F (°C)
CP Airolene Plus
-4 to +120
Tool Oil
(-20 to +50)
Air tool oil
-4 to +60
(-20 to +15)
Air tool oil
+60 to +120
(+15 to +50)
It is recommended that the oil contains a
rust-inhibitor.
Insertion tool
CAUTION
Hot insertion tool
The tip of the insertion tool can become hot and
sharp when used. Touching it can lead to burns and
cuts.
Never touch a hot or sharp insertion tool.
►
Wait until the insertion tool has cooled down
►
before carrying out maintenance work.
NOTICE
Never cool a hot insertion tool in water,
it can result in brittleness and early failure.
Selecting the right insertion tool
Selecting the right insertion tool is a precondition
for proper machine function. It is important to select
insertion tools of high quality to avoid unnecessary
machine damage.
The machine can be destroyed if you use an incorrect
insertion tool.
Recommended insertion tools are listed in the
machine's spare parts list.
Narrow chisel
Moil point
Wide bladed chisel
9800 0606 90a | Original instructions
Viscosity
-
100-150 SUS
(ISO VG 22-32)
225-350 SUS
(ISO VG 46-68)
The narrow chisel is used for
demolition and cutting work in
concrete and other types of
hard materials.
The moil point is only used for
making holes in concrete and
other types of hard materials.
The wide bladed chisel is used
in soft materials, such as
asphalt and frozen ground.
Safety and operating instructions
WARNING
Vibration hazard
Using inserted tools that do not fulfil the criterias
mentioned below, will result in a longer time to
complete a task, and may result in higher levels of
vibration exposure. A worn tool will also cause
increased working time.
►
Make sure that the inserted tool is
well-maintained, not worn out and of the proper
size.
Always use a sharp tool in order to work
►
efficiently.
Fitting and removing the insertion tool
Whenever fitting or removing the insertion tool the
following instructions must be observed:
To prevent an accidental start: switch off the
♦
power supply and disconnect the machine from
the power source. Bleed the machine by pressing
the start and stop device.
Before inserting a tool, lubricate the tool shank
♦
with grease.
Close the tool retainer and check the lock function
♦
by tugging the inserted tool sharply outwards.
Standard retainer, oval collar insertion tools,
hexagonal shank
13