Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

AirBlAde™ And AirBlAde™ deuce
Air compreSSor operAting inStructionS
important safety information — a hazard
that may cause serious injury or loss of
life.
dgr-518-1 (803286)
AirBlAde compreSSor
SpeciFicAtionS:
1/8 Hp (94w)
120VAc, 1 ph, 60 HZ
number of pistons: one
.57 cFm
68 pSi max pressure, noise 53dB
1720 rpm
Shipping Weight: 4.3 kgs (9.4 lbs)
dgr-516 (802611)
AirBlAde deuce
compreSSor
SpeciFicAtionS:
1/6 Hp (125)
120VAc, 1ph, 60Hz
number of pistons: two
1.48 cFm
90 pSi max pressure, noise 58dB
1720 rpm
Shipping Weight: 5.6 kgs (12.2 lbs)
SAFetY precAutionS
important information that tells how to
prevent damage to equipment, or how
to avoid a situation that might cause
minor injury.
operAting inStructionS
When you unpack your unit, look carefully
for damage that might have occurred in
transit.
electricAl requirementS
This unit may only be used at the listed
voltage. Use of low voltage will cause
the motor to overheat. Low voltage can
be suspected when the following condi-
tions exist:
1. Motor does not develop full power or
speed
2. Lights dim when motor starts and remain
dim when starting compressor
3. A fuse blow out occurs at starting or
when load is applied.
4. There are too many motor operated
appliances on the same circuit, which
causes them to not operate properly.
To avoid excessive voltage drop keep
extension cords as short as possible. If
an extension cord is necessary, do not
use less than 16 gauge for 25 feet, 14
gauge for 50 feet, or 12 gauge for 100
feet or more.
generAl inFormAtion
The maximum pressure of the compressor
is 68 PSI. When spraying, the maximum
operating pressure will vary depending
on the size of the fluid nozzle, needle and
/or air cap. For example, when spraying
with the DeVilbiss DAGR™ airbrush with
a .35mm fluid nozzle, the Airblade™ single
piston compressor can maintain 25-30
psi operating pressure. With the same
airbrush, the Airblade Deuce two-piston
compressor can maintain 45-50 psi
operating pressure.
SERVICE bULLETIN
SB-21-092-A
Replaces Sb-21-092
note
Information that you should pay
special attention to.
tHermAl protector
The motor of this compressor is equipped
with a thermal overload protector. If the
motor should overheat, the overload pro-
tector will shut off the motor. If this should
occur, unplug the compressor and allow
the motor to cool (approx. 5 minutes),
remove excess load and restart compres-
sor. If the compressor fails to start, check
for blown fuses. The compressor may
need to cool further before attempting to
restart. If the overload protector shuts off
the motor frequently you may have a low
voltage condition. See conditions under
Electrical Requirements.
AutomAtic SHut-oFF FeAture
This compressor has a built-in pressure
switch that will automatically shut off the
compressor when the airbrush is not in
use. It has been preset at the factory to
give maximum pressure when the airbrush
is attached to the compressor. The com-
pressor will automatically stop when the
airbrush is not in use. It will immediately
begin again as soon as the air is allowed
to flow through the airbrush.
SeAling oF Air HoSe
When attaching the female pipe thread
fitting from your air hose to the compres-
sor, it may be necessary to use a quality
pipe thread sealant or Teflon® pipe thread
PTFE
tape on the threaded air outlet of the
compressor. Failure to do so may cause
an air leak and your compressor will not
shut off as it should.
(Continued on next page)

Publicidad

Tabla de contenido
loading

Resumen de contenidos para DeVilbiss AIRBLADE

  • Página 1 PTFE with the DeVilbiss DAGR™ airbrush with tape on the threaded air outlet of the a .35mm fluid nozzle, the Airblade™ single compressor. Failure to do so may cause piston compressor can maintain 25-30 an air leak and your compressor will not psi operating pressure.
  • Página 2: Grounding Instructions

    Compressor starts and stops during Your airbrush is not using enough air to For single piston Airblade , increase continuous spray use. prevent the back pressure buildup. air pressure to airbrush. For two-piston Airblade Deuce, open the bleeder valve located on the bot- tom of the regulator.
  • Página 3 Sb-21-092-A PAGE 3 bOLETÍN DE MANTENIMIENTO SB-21-092-A Reemplaza al Sb-21-092 inStruccioneS de operAciÓn del compreSor de Aire AirBlAde™ Y AirBlAde™ deuce precAucioneS de SeguridAd AdVertenciA nota precAuciÓn información importante que le indica información importante de seguridad — Información a la que debe prestar cómo prevenir daños al equipo o cómo...
  • Página 4 Y SoluciÓn de proBlemAS condiciÓn cAuSA correcciÓn El compresor arranca y se detiene Su aerógrafo no está usando suficiente Para el compresor Airblade de un durante la atomización continua. aire para prevenir la acumulación de solo pistón, aumente la presión atmos- presión.
  • Página 5: Protecteur Thermique

    172 à 207 kPa (25 à 30 psi). Avec le même aérographe, le compresseur Airblade Deuce à deux pistons peut maintenir une pression de fonctionnement de 310 à 345 kPa (45 à 50 psi). (Suite en page suivante)
  • Página 6: Dépannage

    Airblade , augmentez la pression d'air pression. à l’aérographe. Pour le compresseur Airblade Deuce à deux pistons, ouvrir le purgeur situé au sommet du régulateur. La fonc- tion d’interruption automatique ne fonctionne pas lorsque le purgeur est ouvert.
  • Página 7 Sb-21-092-A PAGE 7...
  • Página 8: Garantía

    PAGE 8 Sb-21-092-A gArAntÍA Este producto está cubierto por la garantía limitada de un aąo de DeVilbiss. centros de venta y servicios de deVilbiss a escala mundial: www.devilbiss.com repintado automotriz de deVilbiss DeVilbiss tiene distribuidores autorizados en todo el mundo.

Este manual también es adecuado para:

Airblade deuce